Message type: E = Error
Message class: FRMLMAN - Message Class for Secondary Data Retrieval
Message number: 005
Message text: More than two value assignmt instances were created for energy profile &1
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
The system processes only the first two
<DS:GLOS.3621B3A9B2CE569BE10000009B38F9B7>value assignment instances</>,
and does so as follows:
It uses the value of the first instance for the value in kilocalories
(kcal).
It uses the value of the second instance for the value in kilojoules
(kJ).
Check the data in the value assignment type for the energy profile.
Error message extract from SAP system. Copyright SAP SE.
FRMLMAN005
- More than two value assignmt instances were created for energy profile &1 ?The SAP error message FRMLMAN005 indicates that more than two value assignment instances have been created for a specific energy profile. This error typically arises in the context of energy management or resource management within SAP, particularly when dealing with value assignments in the framework for managing energy profiles.
Cause: The error is caused by the system detecting that there are more than two value assignment instances for a given energy profile. This situation can occur due to: Incorrect Configuration: The energy profile may be incorrectly configured, allowing for multiple value assignments that exceed the allowed limit. Data Entry Errors: Users may have inadvertently created multiple value assignments for the same energy profile. System Limitations: The system may have a predefined limit on the number of value assignments that can be associated with a single energy profile, and this limit has been exceeded.
Solution: To resolve the FRMLMAN005 error, you can take the following steps: Review Value Assignments:
Get instant SAP help. Sign up for our Free Essentials Plan.
FRMLMAN004
Specify a value assignment type for explosion scope &1 in Customizing
What causes this issue? No value assignment type from which the specification data is read was specified for the explosion scope &V1& in Cust...
FRMLMAN003
No usage was passed at the interface
What causes this issue? The system issues an error message and will not allow you to continue with this transaction until the error is resolved. Syst...
FRMLMAN006
No diets were passed at the interface
What causes this issue? The system issues an error message and will not allow you to continue with this transaction until the error is resolved. Syst...
FRMLMAN008
Value of environment parameter &1 could not be determined
What causes this issue? The environment parameter &V1& does not exist or has no value assigned in Customizing for <LS>Recipe Management...
Click on this link to search all SAP messages.