Message type: E = Error
Message class: FRMLAPI - RMS-FRM: API Messages for Formula
Message number: 290
Message text: Formula &1 is not used to explode component &2: &3 &4
Several alternative explosion options exist for the input component &V2&
. The formula &V1& does not fulfill the prerequisites to be the
preferred option in the explosion and is therefore not taken into
further account in the explosion.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
FRMLAPI290
- Formula &1 is not used to explode component &2: &3 &4 ?The SAP error message FRMLAPI290 indicates that a specific formula is not being used to explode a component in the context of a production order or bill of materials (BOM) explosion. This error typically arises in scenarios involving the use of formulas in production planning or material requirements planning (MRP).
Cause: Formula Not Assigned: The formula specified in the error message is not assigned to the component in the BOM or routing. Incorrect Configuration: The configuration of the formula or the component may not be set up correctly in the system. Inactive Formula: The formula might be inactive or not valid for the specified component. Missing Dependencies: There may be missing dependencies or conditions that prevent the formula from being applied to the component.
Solution: Check Formula Assignment: Go to the BOM or routing where the component is defined and verify if the formula is correctly assigned to the component. Ensure that the formula is intended to be used
Get instant SAP help. Sign up for our Free Essentials Plan.
FRMLAPI289
Substance &1 exists multiple times but is only transferred once
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
FRMLAPI288
Explosion is not possible; I/O materials or I/O substances are missing
What causes this issue? You can specify in Customizing whether the system performs the explosion using I/O materials or I/O substances. Your setting:...
FRMLAPI291
Component &1 was not exploded any further
What causes this issue? One possible reason is that a reaction has taken place.System Response The system issues an error message and will not allow...
FRMLAPI292
Formula &1 contains nutrient composition without usage
What causes this issue? Composition data without a usage exists in the database for the nutrients or nutrient composition of the formula &V1&...
Click on this link to search all SAP messages.