Do you have any question about this error?
Message type: E = Error
Message class: EMDUS -
Message number: 022
Message text: Profile &1 has different interval length to TOU interface &2
You want to bill profile &v1& with a rate that uses the time-of-use
interface &v2& (see <DS:DE.E_MDUSIFACE>Time-of-Use Interface</>). This
is only possible if the profile and the time-of-use interface have the
same <DS:DE.INTSIZEID>interval length</>. This is not the case: The
profile has the interval length &v3& and the time-of-use interface has
the interval length &v4&.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Allocate a suitable rate to the register.
Error message extract from SAP system. Copyright SAP SE.
EMDUS022
- Profile &1 has different interval length to TOU interface &2 ?The SAP error message EMDUS022 indicates that there is a mismatch in the interval lengths between a profile and a Time of Use (TOU) interface. This typically occurs in the context of SAP IS-U (Industry Solution for Utilities) when dealing with billing and metering data.
Cause:
The error arises when the interval length defined in the profile (which could be a meter reading profile or a billing profile) does not match the interval length expected by the TOU interface. This can happen due to:
- Configuration Issues: The profile settings may have been incorrectly configured, leading to discrepancies in expected interval lengths.
- Data Migration: If data has been migrated from another system, the interval lengths may not have been aligned properly.
- Changes in Business Requirements: Changes in business processes or requirements may have led to updates in the TOU interface without corresponding updates in the profile.
Solution:
To resolve the EMDUS022 error, you can take the following steps:
Check Profile Configuration:
- Go to the configuration settings for the profile in question and verify the interval length.
- Ensure that it matches the interval length defined in the TOU interface.
Review TOU Interface Settings:
- Check the TOU interface configuration to confirm the expected interval length.
- Make adjustments if necessary to ensure consistency with the profile.
Adjust Data:
- If the error is due to data migration, you may need to adjust the data to ensure that the interval lengths are consistent across both the profile and the TOU interface.
Consult Documentation:
- Review SAP documentation or notes related to the specific version of IS-U you are using for any known issues or additional configuration steps.
Testing:
- After making changes, perform tests to ensure that the error is resolved and that data flows correctly between the profile and the TOU interface.
Seek Support:
- If the issue persists, consider reaching out to SAP support or consulting with an SAP expert who specializes in IS-U for further assistance.
Related Information:
ES32
(for managing TOU profiles) and ES30
(for managing meter reading profiles).By following these steps, you should be able to identify and resolve the cause of the EMDUS022 error effectively.
Get instant SAP help. Start your 7-day free trial now.
EMDUS021
Profile &1 cannot be billed with rate &2
What causes this issue? You have allocated profile &v1& to a register that is billed using rate &v2&. Due to its <DS:DE.RTPCATEGOR...
EMDUS020
Date field is empty
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EMDUS023
Profile allocation incomplete for device &1 &2
What causes this issue? No profile with the role category <LS>Measurement</> is allocated at date and time &v4& for the interval ...
EMDUS024
Error during rebilling for document &1: MDUS request required
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.