Message type: E = Error
Message class: EL - IS-U meter reading data processing
Message number: 345
Message text: Cosine phi cannot be calculated for &1
Cosine phi validation &v2& for device &v3& cannot be carried out
because division by zero was necessary.
The cosine phi is calculated as follows:
Cosine phi = active energy / (root(active energy? + reactive energy?))
Division by zero is only possible if both active and reactive energy
are 0.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Check your entries.
Error message extract from SAP system. Copyright SAP SE.
EL345
- Cosine phi cannot be calculated for &1 ?The SAP error message EL345, which states "Cosine phi cannot be calculated for &1," typically occurs in the context of electrical engineering and power management within SAP systems, particularly when dealing with electrical consumption and power factor calculations.
Cause: The error usually arises due to one of the following reasons: Missing Data: The necessary data for calculating the cosine phi (power factor) is missing or incomplete. This could include missing measurements for active power (kW) or reactive power (kVAR). Invalid Values: The values provided for active or reactive power may be invalid or zero, which makes it impossible to calculate the cosine phi.
Configuration Issues: There may be configuration issues in the system related to the measurement points or the way the data is being collected. Data Type Mismatch: The data types of the values being used for the calculation may not be compatible or may not be in the expected format.
Solution: To resolve the EL345 error,
Get instant SAP help. Sign up for our Free Essentials Plan.
EL344
Meter reading orders still exist for the devices to be removed
What causes this issue? Future meter reading orders are deleted when you save.System Response The system issues an error message and will not allow ...
EL343
Tolerance factor 0 for &1, interval &2
What causes this issue? You cannot specify 0 for the tolerance limit. The tolerance factor is calculated based on parameters defined in table TE121 (...
EL346
Device &1, register &2 estimated successfully
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EL347
Representativity check not possible for device &1, register &2
What causes this issue? The system issues an error message and will not allow you to continue with this transaction until the error is resolved. Syst...