Do you have any question about this error?
Message type: E = Error
Message class: EL - IS-U meter reading data processing
Message number: 189
Message text: Interval period: For device &1, register &2
A &v3& with a higher priority is planned for this device in the
interval period.
You have selected <LS>Always read</> for the meter reading reason
entered (Table <LS>Priority of MR reasons for interval check</>) for
the current &v4&. Only billing is suppressed in this case.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
EL189
- Interval period: For device &1, register &2 ?The SAP error message EL189, which states "Interval period: For device &1, register &2," typically occurs in the context of energy management and metering within the SAP IS-U (Industry Solution for Utilities) module. This error indicates that there is an issue with the interval data for a specific device and register.
Cause:
The error can be caused by several factors, including:
- Missing Interval Data: The system may not have the required interval data for the specified device and register.
- Incorrect Configuration: The configuration settings for the device or register may not be set up correctly, leading to discrepancies in the expected interval periods.
- Data Consistency Issues: There may be inconsistencies in the data stored in the database, such as overlapping or missing intervals.
- Time Period Issues: The time period for which the data is being requested may not align with the available data intervals.
Solution:
To resolve the EL189 error, you can take the following steps:
Check Interval Data: Verify that the interval data for the specified device and register exists in the system. You can do this by checking the relevant tables or using transaction codes like EL31 or EL32 to view interval data.
Review Configuration: Ensure that the device and register configurations are correct. Check the settings in the device master record and the register configuration to ensure they are aligned with the expected interval periods.
Data Consistency Check: Run consistency checks on the interval data to identify any discrepancies. You can use transaction codes like EL37 to perform data consistency checks.
Adjust Time Periods: If the error is related to a specific time period, ensure that the time period you are querying matches the available interval data. Adjust the time frame if necessary.
Consult Documentation: Refer to SAP documentation or notes related to the EL189 error for any specific guidance or patches that may address the issue.
Contact Support: If the issue persists after performing the above checks, consider reaching out to SAP support for further assistance.
Related Information:
By following these steps, you should be able to identify and resolve the cause of the EL189 error in your SAP system.
Get instant SAP help. Start your 7-day free trial now.
EL188
Device &1 register &2: printing corr. order for plausible MR not possible
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EL187
Device &1 register &2: tol. limit val. without expctd consump. not poss.
What causes this issue? It is not possible to calculate expected consumption. This calculation provides the basis for the tolerance limit validatatio...
EL190
Only use "no cover sheet" with "meter reading unit" and "print order"
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EL191
No meter reading for device &1 register &2 due to meter reading interval
What causes this issue? A &v3& has already been planned for this device in the interval specified for the meter reading unit. The current ord...
Click on this link to search all SAP messages.