Message type: E = Error
Message class: EL - IS-U meter reading data processing
Message number: 189
Message text: Interval period: For device &1, register &2
A &v3& with a higher priority is planned for this device in the
interval period.
You have selected <LS>Always read</> for the meter reading reason
entered (Table <LS>Priority of MR reasons for interval check</>) for
the current &v4&. Only billing is suppressed in this case.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
EL189
- Interval period: For device &1, register &2 ?The SAP error message EL189, which states "Interval period: For device &1, register &2," typically occurs in the context of energy management and metering within the SAP IS-U (Industry Solution for Utilities) module. This error indicates that there is an issue with the interval data for a specific device and register.
Cause: The error can be caused by several factors, including: Missing Interval Data: The system may not have the required interval data for the specified device and register. Incorrect Configuration: The configuration settings for the device or register may not be set up correctly, leading to discrepancies in the expected interval periods. Data Consistency Issues: There may be inconsistencies in the data stored in the database, such as overlapping or missing intervals. Time Period Issues: The time period for which the data is being requested may not align with the available data intervals.
Solution: To resolve the EL189 error, you can take the following steps: Check Interval Data:
Get instant SAP help. Sign up for our Free Essentials Plan.
EL188
Device &1 register &2: printing corr. order for plausible MR not possible
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EL187
Device &1 register &2: tol. limit val. without expctd consump. not poss.
What causes this issue? It is not possible to calculate expected consumption. This calculation provides the basis for the tolerance limit validatatio...
EL190
Only use "no cover sheet" with "meter reading unit" and "print order"
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EL191
No meter reading for device &1 register &2 due to meter reading interval
What causes this issue? A &v3& has already been planned for this device in the interval specified for the meter reading unit. The current ord...
Click on this link to search all SAP messages.