Message type: E = Error
Message class: EL - IS-U meter reading data processing
Message number: 187
Message text: Device &1 register &2: tol. limit val. without expctd consump. not poss.
It is not possible to calculate expected consumption. This calculation
provides the basis for the tolerance limit validatation (meaning it
defines upper and lower limits). Therefore, the validation cannot be
carried out.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
See your SAP system administrator.
Error message extract from SAP system. Copyright SAP SE.
EL187
- Device &1 register &2: tol. limit val. without expctd consump. not poss. ?The SAP error message EL187 indicates an issue related to the registration of a device in the SAP system, specifically in the context of energy management or utility billing. The message reads: "Device &1 register &2: tol. limit val. without expctd consump. not poss." This translates to a situation where the tolerance limit value for a device register is not possible without the expected consumption being present.
Cause:
- Missing Consumption Data: The error typically arises when the system expects a certain level of consumption data for a device register, but that data is either missing or not within the expected range.
- Configuration Issues: There may be a misconfiguration in the device settings or the tolerance limits set for the registers.
- Data Entry Errors: Incorrect data entry or missing entries in the device master data or register data can lead to this error.
- Threshold Settings: The tolerance limits set for the device registers may not align with the actual consumption patterns, leading to discrepancies.
Solution:
- Check Consumption Data: Verify that the consumption data for the device and its registers is correctly entered and available in the system. Ensure that the expected consumption values are present.
- Review Device Configuration: Check the configuration settings for the device and its registers. Ensure that the tolerance limits are set correctly and are appropriate for the expected consumption.
- Adjust Tolerance Limits: If necessary, adjust the tolerance limits for the device registers to align with the actual consumption data.
- Data Validation: Perform a validation of the data entries related to the device and its registers to ensure there are no discrepancies or missing information.
- Consult Documentation: Refer to SAP documentation or help resources for specific guidance on handling this error in the context of your SAP version and configuration.
Related Information:
EL31
(for device management) or EL22
(for register management) to access and review the relevant data.By following these steps, you should be able to identify the root cause of the EL187 error and implement the necessary solutions to resolve it.
Get instant SAP help. Start your 7-day free trial now.
EL186
Reading for device &1, reg. &2 could not be calculated automatically
What causes this issue? The register has neither a rate category nor a rate type. As a result, it is not possible to define either a rate or a weight...
EL185
Device &1 register &2: estimation could not determine a valid MR
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EL188
Device &1 register &2: printing corr. order for plausible MR not possible
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EL189
Interval period: For device &1, register &2
What causes this issue? A &v3& with a higher priority is planned for this device in the interval period. You have selected <LS>Always r...
Click on this link to search all SAP messages.