Do you have any question about this error?
Message type: E = Error
Message class: EL - IS-U meter reading data processing
Message number: 030
Message text: &1: Overflow for device &2 reg. &3: Current MR lower than previous MR
The overflow check (check 20) is active. It has been determined that
the current meter reading is smaller than the previous meter reading.
Therefore, an overflow appears to exist.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
The meter reading can either be reset, or validated by clicking on the
CORRECTION button.
Error message extract from SAP system. Copyright SAP SE.
EL030
- &1: Overflow for device &2 reg. &3: Current MR lower than previous MR ?The SAP error message EL030 indicates an overflow issue related to a specific device and its measurement reading (MR). This error typically occurs in the context of energy management or utility billing within SAP IS-U (Industry Solution for Utilities).
Cause:
The error message EL030 is triggered when the current measurement reading (MR) for a device is lower than the previous measurement reading. This situation can occur due to several reasons:
- Incorrect Meter Reading: A manual entry error where the current reading is mistakenly entered as lower than the previous reading.
- Meter Reset: If the meter has been reset or replaced, it may start counting from a lower value, leading to this error.
- Data Migration Issues: During data migration or system upgrades, incorrect values may have been transferred, causing inconsistencies in the measurement records.
- Faulty Meter: A malfunctioning meter may report incorrect readings.
Solution:
To resolve the EL030 error, you can take the following steps:
- Verify Meter Readings: Check the current and previous meter readings for accuracy. Ensure that the current reading is indeed higher than the previous reading.
- Correct Manual Entries: If the current reading was entered incorrectly, correct it in the system to reflect the accurate value.
- Check for Meter Resets: If the meter was reset, ensure that the new readings are recorded correctly and that the system is updated to reflect this change.
- Inspect the Meter: If you suspect a faulty meter, have it inspected or replaced as necessary.
- Consult Documentation: Review SAP documentation or consult with your SAP support team for specific instructions related to your system configuration.
Related Information:
If the issue persists after following these steps, it may be beneficial to engage with SAP support for further assistance.
Get instant SAP help. Start your 7-day free trial now.
EL029
Enter an installation
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EL028
No meter reading order can be allocated to the meter reading result
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EL031
An internal error has occurred during selection of a contract
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EL032
Customer & has no contracts
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.