Do you have any question about this error?
Message type: E = Error
Message class: EHQ - QM: Messages
Message number: 102
Message text: Master inspection characteristic missing for plant &1
You have specified the plant &V1&, but no master inspection
characteristic. That is not permitted.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Enter a valid combination of master inspection characteristic and plant.
You can also use the input help to make your selection.
Error message extract from SAP system. Copyright SAP SE.
EHQ102
- Master inspection characteristic missing for plant &1 ?The SAP error message EHQ102, which states "Master inspection characteristic missing for plant &1," typically occurs in the context of Quality Management (QM) when you are trying to create or process a quality inspection lot, and the system cannot find the required master inspection characteristic (MIC) for the specified plant.
Cause:
- Missing Master Inspection Characteristic: The primary cause of this error is that the master inspection characteristic (MIC) you are trying to use is not defined for the specified plant in the system.
- Incorrect Configuration: The MIC may not be properly configured or assigned to the relevant material or inspection plan.
- Plant-Specific Settings: The MIC might exist in the system but is not assigned to the specific plant you are working with.
Solution:
To resolve the EHQ102 error, you can follow these steps:
Check Master Inspection Characteristics:
- Go to the transaction code
QS21
(Create Master Inspection Characteristic) orQS22
(Change Master Inspection Characteristic).- Verify if the MIC exists for the specified plant. If it does not exist, you will need to create it.
Assign MIC to Plant:
- If the MIC exists but is not assigned to the plant, you can assign it by using the transaction code
QS22
to modify the MIC and include the relevant plant.Review Inspection Plans:
- Check the inspection plan associated with the material. Use transaction code
QP01
(Create Inspection Plan) orQP02
(Change Inspection Plan) to ensure that the MIC is included in the inspection plan for the correct plant.Check Material Master:
- Ensure that the material master record is correctly set up for the plant in question. Use transaction code
MM02
to check the material master data.Consult Documentation:
- If you are unsure about the configuration, refer to SAP documentation or consult with your SAP QM consultant for guidance on setting up master inspection characteristics.
Related Information:
Transaction Codes:
QS21
: Create Master Inspection CharacteristicQS22
: Change Master Inspection CharacteristicQP01
: Create Inspection PlanQP02
: Change Inspection PlanMM02
: Change Material MasterQuality Management (QM) Module: Understanding the QM module and its components, such as inspection plans, MICs, and quality inspection lots, is crucial for troubleshooting this error.
SAP Notes: Check for any relevant SAP Notes that may address specific issues related to this error message.
By following these steps, you should be able to identify and resolve the issue causing the EHQ102 error in SAP.
Get instant SAP help. Start your 7-day free trial now.
EHQ101
Specifications are only permitted for compositions
What causes this issue? You have specified specification &V1&, but you have not set the <LS>Composition</> indicator. This is not...
EHQ100
Invalid entry in combination with Composition indicator
What causes this issue? You have set the <LS>Composition</> indicator. This is only possible in combination with the entry of a specifica...
EHQ103
Characteristic type &1 already exists
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EHQ104
Characteristic missing for characteristic value &1
What causes this issue? A characteristic is missing for the characteristic value &V1&. When you specify the characteristic and the characteri...
Click on this link to search all SAP messages.