Do you have any question about this error?
Message type: E = Error
Message class: EG - IS-U device management
Message number: 606
Message text: Invalid values for rating, primary voltage, and/or secondary voltage
At least one value does not have the correct format.
Values in the database for rating, primary voltage, and secondary
voltage must meet the following requirements:
Rating: 8 digits
Primary voltage: 6 digits
Secondary voltage: 6 digits
<ZH>Example:</>
The primary voltage is 12,345.6 kv.
In the database, you must enter the value as "123456".
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Processing is terminated.
Make sure that all values for rating, primary voltage, and secondary
voltage have the correct format.
Error message extract from SAP system. Copyright SAP SE.
EG606
- Invalid values for rating, primary voltage, and/or secondary voltage ?The SAP error message EG606, which states "Invalid values for rating, primary voltage, and/or secondary voltage," typically occurs in the context of electrical equipment or asset management within SAP, particularly when dealing with equipment specifications in the SAP PM (Plant Maintenance) or SAP PS (Project System) modules.
Cause:
The error is usually triggered by one or more of the following issues:
- Incorrect Input Values: The values entered for the rating, primary voltage, or secondary voltage do not conform to the expected format or range defined in the system.
- Missing Configuration: The system may not have the necessary configuration or master data set up for the specific equipment or asset type.
- Data Type Mismatch: The values provided may not match the expected data types (e.g., entering a string instead of a number).
- Inconsistent Units: The units of measurement for voltage or rating may not be consistent with what the system expects (e.g., volts vs. kilovolts).
- Validation Rules: There may be specific validation rules in place that the entered values do not satisfy.
Solution:
To resolve the EG606 error, you can take the following steps:
- Check Input Values: Review the values you have entered for rating, primary voltage, and secondary voltage. Ensure they are within the acceptable range and in the correct format.
- Review Master Data: Ensure that the relevant master data (e.g., equipment master records) is correctly configured. Check if the equipment type supports the specified ratings and voltages.
- Consult Documentation: Refer to the SAP documentation or configuration guides for the specific module you are working with to understand the expected values and formats.
- Validate Units: Ensure that the units of measurement are consistent with what the system expects. If necessary, convert the values to the correct units.
- Check Custom Validation Rules: If your organization has implemented custom validation rules, review them to ensure that the values you are entering comply with these rules.
- Seek Help from SAP Support: If the issue persists after checking the above points, consider reaching out to your SAP support team or consulting SAP Notes for any known issues related to this error.
Related Information:
By following these steps, you should be able to identify and correct the cause of the EG606 error in SAP.
Get instant SAP help. Start your 7-day free trial now.
EG605
Combination rating &1, primary vltge &2, secondary vltge &3 not permitted
What causes this issue? You have entered an impermissible combination of rating (&V1&), primary voltage (&V2&), and secondary voltage...
EG603
Enter a valid value for the secondary voltage
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EG607
Enter a value for the rating
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EG608
Enter a value for the primary voltage
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.