Message type: E = Error
Message class: EG - IS-U device management
Message number: 605
Message text: Combination rating &1, primary vltge &2, secondary vltge &3 not permitted
You have entered an impermissible combination of rating (&V1&), primary
voltage (&V2&), and secondary voltage (&V3&).
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Use the input help (F4) to selected a valid combination. auszuwShlen.
Error message extract from SAP system. Copyright SAP SE.
EG605
- Combination rating &1, primary vltge &2, secondary vltge &3 not permitted ?The SAP error message EG605 indicates that there is an issue with the combination of the rating and voltage levels for an electrical component, such as a transformer or a motor. This error typically arises in the context of electrical engineering or equipment management within SAP, particularly in modules related to Plant Maintenance (PM) or Materials Management (MM).
Cause:
The error message EG605 is triggered when the combination of the following parameters does not meet the predefined criteria in the system:
The specific combination of these parameters may not be allowed due to:
To resolve the EG605 error, you can take the following steps:
Check Configuration: Review the configuration settings in the SAP system for the electrical components. Ensure that the allowed combinations of ratings and voltages are correctly defined.
Verify Data Entry: Double-check the data entered for the component. Ensure that the rating, primary voltage, and secondary voltage are entered correctly and are valid.
Review Master Data: Look into the master data for the equipment or material in question. Ensure that the specifications for the component are correctly defined and that there are no discrepancies.
Consult Documentation: Refer to the SAP documentation or configuration guides related to electrical components to understand the valid combinations and any restrictions that may apply.
Seek Help from SAP Support: If the issue persists after checking the above points, consider reaching out to SAP support or your internal SAP team for further assistance. They may provide insights based on the specific configuration of your SAP environment.
IE02
(Change Equipment) or MM02
(Change Material) to review and modify the relevant data.By following these steps, you should be able to identify and resolve the cause of the EG605 error in SAP.
Get instant SAP help. Start your 7-day free trial now.
EG603
Enter a valid value for the secondary voltage
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EG602
Enter a valid value for the primary voltage
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EG606
Invalid values for rating, primary voltage, and/or secondary voltage
What causes this issue? At least one value does not have the correct format. Values in the database for rating, primary voltage, and secondary voltag...
EG607
Enter a value for the rating
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.