Do you have any question about this error?
Message type: E = Error
Message class: EE_QD -
Message number: 119
Message text: Inst. &4 Dev. &1 Reg. &2 MRDate &3: No unique previous MR doc.
The meter reading result has the quantity determination status <ZH>3</>
- <LS>Quantity Determination Trigger Generated</>.
You tried to execute quantity determination again for the
<DS:GLOS.4BE62DF04D2544D1E10000000A421947>quantity determination trigger
</>. However, as no unique previous meter reading document exists, a
quantity could still not be determined.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Check whether meter reading orders without a result exist for the device
<ZH>before</> the current meter reading date, for which no meter
reading results have yet been entered.
Once you have entered a unique previous meter reading, you can execute
quantity determination again for this meter reading result.
Error message extract from SAP system. Copyright SAP SE.
EE_QD119
- Inst. &4 Dev. &1 Reg. &2 MRDate &3: No unique previous MR doc. ?The SAP error message EE_QD119 typically indicates that there is an issue with the material requirements (MR) document processing in the system. This error occurs when the system cannot find a unique previous material requirements document (MR document) for the specified instance, development, and registration numbers.
Cause:
- Missing Previous MR Document: The system is unable to locate a previous MR document that is required for the current processing.
- Multiple Previous MR Documents: There may be multiple MR documents that match the criteria, leading to ambiguity.
- Data Inconsistency: There could be inconsistencies in the data, such as incorrect entries or missing records in the database.
- Configuration Issues: The configuration settings for the material requirements planning (MRP) might not be set up correctly.
Solution:
- Check Previous MR Documents: Verify if there are any previous MR documents related to the instance and development numbers. You can do this by checking the relevant tables in the SAP database.
- Ensure Uniqueness: If there are multiple MR documents, ensure that the system can identify a unique previous document. This may involve cleaning up duplicate entries or correcting the data.
- Review Configuration: Check the configuration settings for MRP in the SAP system to ensure they are set up correctly. This may involve consulting with your SAP Basis or configuration team.
- Data Consistency Check: Run data consistency checks to identify and resolve any discrepancies in the database that may be causing the issue.
- Consult Documentation: Refer to SAP documentation or notes related to this error message for any specific guidance or patches that may be available.
Related Information:
MD04
(Stock/Requirements List) or MD05
(MRP List) to analyze the material requirements and see if there are any discrepancies.By following these steps, you should be able to identify the root cause of the error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
EE_QD118
Inst. &4 Dev. &1 Reg. &2 MRDate &3: Current gas data not available
What causes this issue? The meter reading result has the quantity determination status <ZH>3</> - <LS>Quantity Determination Trigge...
EE_QD109
Dev. &1, reg. &2, chge date &3: Chge to GVCF of register &4 => Long text
What causes this issue? You want to make a change to the <ZH>determined gas volume correction factor from the register</> on the specifie...
EE_QD120
Inst. &4 Dev. &1 Reg. &2 MRDate &3: Quantity determination not successful
What causes this issue? The meter reading result has the quantity determination status <ZH>3</> - <LS>Quantity Determination Trigge...
EE_QD121
Inst. &4 Dev. &1 Reg. &2 MRDate &3: Quantity determination not necessary
What causes this issue? The meter reading result has the quantity determination status <ZH>3</> - <LS>Quantity Determination Trigge...