Do you have any question about this error?
Message type: E = Error
Message class: EB - IS-U invoicing
Message number: 704
Message text: Report &1 not intended for parallel processing
You have started report &v1& several times in parallel runs. The current
program run tried to process one of the documents that has already been
processed by one of the parallel runs.
Processing is terminated.
Report &V1& can only be repeatedly started in parallel runs if the
selections of the individual runs do not overlap.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
EB704
- Report &1 not intended for parallel processing ?The SAP error message EB704, which states "Report &1 not intended for parallel processing," typically occurs when you attempt to execute a report in parallel processing mode, but the report is not designed to support this feature. Here’s a breakdown of the cause, potential solutions, and related information:
Cause:
- Report Design: The report you are trying to run has not been coded to support parallel processing. This can happen if the report uses global variables, shared resources, or has dependencies that do not allow it to be executed in parallel.
- System Configuration: The system may be configured to run certain reports in parallel by default, but the specific report does not have the necessary coding to handle multiple instances running simultaneously.
Solution:
Run in Serial Mode: The simplest solution is to run the report in serial mode instead of parallel processing. You can do this by:
- Going to the transaction where you execute the report.
- Look for an option to run the report in "single" or "serial" mode.
- If you are using a background job, ensure that the job is set to run in a non-parallel mode.
Modify the Report: If you have access to the ABAP code and the necessary authorizations, you can modify the report to support parallel processing. This involves:
- Reviewing the code for any global variables or shared resources that could cause issues when multiple instances are running.
- Implementing proper handling for parallel execution, such as using local variables or ensuring that data access is thread-safe.
Consult Documentation: Check the SAP documentation or notes related to the specific report to see if there are any recommendations or known issues regarding parallel processing.
Contact SAP Support: If you are unable to resolve the issue, consider reaching out to SAP support for assistance. They may provide insights or patches if the report is part of standard SAP functionality.
Related Information:
By following these steps, you should be able to address the EB704 error and successfully execute your report.
Get instant SAP help. Start your 7-day free trial now.
EB703
Print document &1: neither equipment number or contact allocated
What causes this issue? None of the print document lines contains an equipment or contract numner. The meter reading unit cannot therefore be determi...
EB702
Print document &1: contract &2 is not allocated to a logical device no.
What causes this issue? Using date &v3& a logical device number cannot be found for contract &v2&.System Response Print document &am...
EB705
Module ISU_INV_BILLDOC_PROCESSING can only be used for simulations.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EB800
Invoicing document cannot be reversed
What causes this issue? True document &v2& has already been posted for statistical request document &v2&. Therefore you cannot revers...
Click on this link to search all SAP messages.