How To Fix EA122 - Error while setting status for container '&' with IDoc links


SAP Error Message - Details

  • Message type: E = Error

  • Message class: EA - IDoc Basis Messages

  • Message number: 122

  • Message text: Error while setting status for container '&' with IDoc links

  • Show details Hide details
  • What causes this issue?

    Container '&v1&' with the links between IDoc and application documents
    could not be processed. The status was to be set in accordance with the
    IDoc archiving performed.

    System Response

    This message is for information purposes.

    How to fix this error?

    Please check whether the container is still in the system and whether
    there may be an inconsistency in the workflow.

    Error message extract from SAP system. Copyright SAP SE.


Smart SAP Assistant

  • What is the cause and solution for SAP error message EA122 - Error while setting status for container '&' with IDoc links ?

    The SAP error message EA122 indicates that there is an issue with setting the status for a container that has IDoc links. This error typically arises in scenarios where IDocs (Intermediate Documents) are used for data exchange between SAP systems or between SAP and non-SAP systems. The error can occur due to various reasons, including configuration issues, data inconsistencies, or problems with the IDoc processing.

    Causes of EA122 Error

    1. IDoc Status Issues: The IDoc may be in a status that does not allow for the operation you are trying to perform. For example, if the IDoc is already processed or in an error state, you may not be able to change its status.

    2. Container Configuration: There may be issues with the configuration of the container or the way it is linked to the IDoc. This could include missing or incorrect settings in the IDoc processing configuration.

    3. Data Inconsistencies: The data being processed may have inconsistencies or errors that prevent the status from being set correctly.

    4. Authorization Issues: The user attempting to set the status may not have the necessary authorizations to perform this action.

    5. Technical Issues: There could be underlying technical issues, such as database locks or system performance problems, that are preventing the status change.

    Solutions to EA122 Error

    1. Check IDoc Status: Review the status of the IDoc linked to the container. You can use transaction code WE02 or WE05 to monitor IDocs and their statuses. Ensure that the IDoc is in a state that allows for status changes.

    2. Review Configuration: Verify the configuration settings related to the IDoc processing and the container. Ensure that all necessary settings are correctly configured.

    3. Data Validation: Check the data being processed for any inconsistencies or errors. Correct any issues found in the data.

    4. User Authorizations: Ensure that the user has the necessary authorizations to change the status of the container. You may need to consult with your SAP security team to verify this.

    5. System Logs: Check the system logs (transaction SM21) for any additional error messages or warnings that may provide more context about the issue.

    6. Reprocessing IDocs: If the IDoc is in an error state, you may need to reprocess it. You can use transaction code BD87 to reprocess IDocs that have failed.

    7. Consult SAP Notes: Look for relevant SAP Notes that may address this specific error. SAP Notes often provide solutions or workarounds for known issues.

    8. Technical Support: If the issue persists, consider reaching out to SAP support for further assistance. Provide them with detailed information about the error, including the context in which it occurs.

    Related Information

    • IDoc Processing: Understanding how IDocs work in SAP and the various statuses they can have is crucial for troubleshooting this error.
    • Transaction Codes: Familiarize yourself with transaction codes like WE02, WE05, BD87, and SM21 for monitoring and managing IDocs and system logs.
    • SAP Documentation: Refer to SAP's official documentation for detailed information on IDoc processing and error handling.

    By following these steps, you should be able to identify the cause of the EA122 error and implement a solution to resolve it.

    • Do you have any question about this error?


      Upgrade now to chat with this error.


Instant HelpGet instant SAP help. Start your 7-day free trial now.


Related SAP Error Messages

Click the links below to see the following related messages:
  • EA121 IDoc reloaded
    What causes this issue? The IDoc was reloaded. Archive : &v1& Archive date : &v2& Release : &v3& ...

  • EA120 IDoc archived
    What causes this issue? The IDoc was archived. Archive : &v1& Archive date : &v2& Release : &v3& ...

  • EA123 No queue entries selected
    Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...

  • EA124 Select an IDoc number by clicking a link
    Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...

Click on this link to search all SAP messages.


Rating
The AI Support Assistant is great. It provides comprehensive assistance even on the most difficult issues. I highly recommend this service.
Rate 1
John Jordan
SAP Consultant & Author