Do you have any question about this error?
Message type: E = Error
Message class: E9 - General IS-U Error Messages
Message number: 878
Message text: Internal error: Entry of tables &1 required in function module &2
You called the function module, but the specified table was not
transferred. The function module requires this table to perform the
function.
An error message was generated.
Note the following:
The message text and the message number
The name of the internal table and the name of the module/form
The transaction/report
The entries that led to this error
Send a message with these specifications to SAP.
Error message extract from SAP system. Copyright SAP SE.
E9878
- Internal error: Entry of tables &1 required in function module &2 ?The SAP error message E9878, which states "Internal error: Entry of tables &1 required in function module &2," typically indicates that there is an issue with the internal processing of a function module in SAP. This error suggests that the function module is expecting certain entries in a specified table, but those entries are either missing or not being processed correctly.
Cause:
- Missing Data: The function module is trying to access a table that does not have the required entries.
- Incorrect Configuration: There may be a configuration issue where the expected data is not set up correctly in the system.
- Program Logic Error: There could be a bug or logical error in the custom code or standard SAP code that is calling the function module.
- Data Inconsistency: There may be inconsistencies in the data that are causing the function module to fail.
Solution:
- Check Table Entries: Verify that the required entries in the specified table (&1) exist. You can do this by using transaction codes like SE11 (Data Dictionary) or SE16 (Data Browser) to inspect the table.
- Review Function Module: Use transaction SE37 to review the function module (&2) and check its documentation to understand what data it expects.
- Debugging: If you have access to the development environment, you can debug the function module to see where it is failing and why the required entries are not being found.
- Check Custom Code: If the function module is being called from custom code, review that code for any logical errors or missing data handling.
- Consult SAP Notes: Check the SAP Support Portal for any relevant SAP Notes that might address this specific error or provide patches.
- Contact SAP Support: If the issue persists and you cannot find a resolution, consider reaching out to SAP Support for assistance.
Related Information:
By following these steps, you should be able to identify the cause of the error and implement a solution.
Get instant SAP help. Start your 7-day free trial now.
E9877
Internal error: Parameter &1 in FM &2 contains invalid value &3
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
E9876
Internal error: Conversion of screen to internal format incorrect
What causes this issue? An error occurred in function module &V1& for field &V2& during conversion of a meter reading for screen disp...
E9879
Internal error: Insertion error for internal table &1 in &2 &3
What causes this issue? An error has occurred during insertion into an internal table. A program error probably exists. A data inconsistency may also...
E9880
Internal error: Change error for internal table &1 in &2 &3
What causes this issue? An error has occurred during an internal table change. A program error probably exists. A data inconsistency may also exist.S...
Click on this link to search all SAP messages.