Message text: No indicators converted in table(s) &1
No data records existed for which the DELFLG field was set.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
DG884
- No indicators converted in table(s) &1 ?The SAP error message DG884 "No indicators converted in table(s) &1" typically occurs during the data conversion process, particularly when working with the Data Migration Workbench (DMW) or during the execution of a data migration program. This message indicates that the system did not find any indicators to convert in the specified table(s).
Cause:
- No Data to Convert: The most common cause is that there are no records in the specified table(s) that meet the criteria for conversion.
- Incorrect Configuration: The configuration settings for the data migration might not be set up correctly, leading to no indicators being identified for conversion.
- Data Selection Criteria: The selection criteria used for the conversion might be too restrictive, resulting in no data being selected for processing.
- Table Locking: If the table is locked or if there are issues with database access, it may prevent the conversion process from identifying any indicators.
Solution:
- Check Data Availability: Verify that there are records in the specified table(s) that should be converted. You can do this by running a simple query or report to check the data.
- Review Configuration: Ensure that the configuration for the data migration is set up correctly. Check the mapping and transformation rules to ensure they are correctly defined.
- Adjust Selection Criteria: If the selection criteria are too restrictive, consider broadening them to include more records for conversion.
- Check for Locks: Ensure that there are no locks on the table that could prevent data access. You can check for locks using transaction codes like SM12.
- Review Logs: Check the logs for any additional error messages or warnings that might provide more context about why the indicators were not converted.
- Test with Sample Data: If possible, test the conversion process with a smaller set of data to see if the issue persists.
Related Information:
If the issue persists after following these steps, consider reaching out to SAP support or consulting with a technical expert who specializes in SAP data migration.
Get instant SAP help. Start your 7-day free trial now.
DG883
Conversion completed successfully
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
DG882
E: &1 entries in master data table (DGTMD) not converted
What causes this issue? The database table for dangerous goods master data (DGTMD) could not be converted completely. The number of converted entries...
DG885
Entries for dangerous goods regulation &1 are not unique
What causes this issue? Several dangerous goods regulations were found in the Customizing table for the combination mode-of-transport category (&...
DG886
Table cannot be locked; conversion is not done
What causes this issue? The dangerous goods tables DGTMD and DGTM2 could not be locked as individual dangerous goods data records are already locked ...