Do you have any question about this error?
Message type: E = Error
Message class: CY - Capacity Requirements Planning
Message number: 693
Message text: Unit of measure & not found
The scale &V1& is not defined in Customizing.
The system cannot generate the planning table.
You should enter the scale in Customizing for capacity planning
or enter a valid scale in the profile used for the planning table.
Error message extract from SAP system. Copyright SAP SE.
CY693
- Unit of measure & not found ?The SAP error message CY693, which states "Unit of measure & not found," typically occurs when the system cannot find a specified unit of measure (UoM) in the relevant master data or configuration settings. This can happen in various contexts, such as during the creation of a material, when processing a transaction, or while performing inventory management tasks.
Causes:
- Missing UoM in Master Data: The specified unit of measure may not be defined in the material master or other relevant master data records.
- Incorrect UoM Configuration: The unit of measure may not be properly configured in the system, or it may not be linked to the material or product.
- Data Entry Errors: There may be a typographical error in the unit of measure entered by the user.
- Inconsistent UoM Settings: The unit of measure may not be consistent with the settings in the relevant configuration tables.
Solutions:
Check Material Master:
- Go to the material master record (transaction code MM03) and check if the unit of measure is defined under the relevant views (e.g., Basic Data, Purchasing, Sales).
- If the UoM is missing, you can add it using transaction code MM02 (Change Material) or MM01 (Create Material).
Verify UoM Configuration:
- Use transaction code CUNI to check the unit of measure settings in the system.
- Ensure that the UoM is defined in the UoM table and is linked to the appropriate material types.
Correct Data Entry:
- Double-check the unit of measure entered in the transaction to ensure there are no typographical errors.
- Ensure that the UoM is entered in the correct format (e.g., using the correct abbreviation).
Review UoM Conversion:
- If applicable, check if there are any conversion factors defined for the UoM. Ensure that the conversion is set up correctly in the material master.
Consult Documentation:
- Review SAP documentation or help files for additional guidance on UoM settings and configurations.
Contact SAP Support:
- If the issue persists after checking the above points, consider reaching out to your SAP support team or consulting SAP Notes for any known issues related to this error.
Related Information:
By following these steps, you should be able to identify and resolve the cause of the CY693 error in SAP.
Get instant SAP help. Start your 7-day free trial now.
CY692
Time axis profile & not found
What causes this issue? The time scale profile &V1& has not been defined in customizing for capacity planning.System Response The system can...
CY691
Graphics profile & & & no found
What causes this issue? The graphics profile &V1& &V2& &V3& could not be found.System Response The system finishes drawing t...
CY694
No components exist
What causes this issue? According to the strategy profile you intend to carry out a material availability check. However, no material components are ...
CY695
Component & with rqmts date & and rqmts quantity & not available
What causes this issue? Although there is remaining available capacity at the calculated point in time &V2& but not the material components r...
Click on this link to search all SAP messages.