Do you have any question about this error?
Message type: E = Error
Message class: CVIV_VAL - Supplier (vendor) validations
Message number: 011
Message text: Subrange "&1" plant "&2": PROACT control prof "&3" not in TWVMO
You cannot use value &V3& in the field PROACT control prof (Profile for
transferring material data via IDoc PROACT) (LFM2-PAPRF) because it is
not defined in customizing table TWVMO.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Option 1: Enter a value that is permitted according to customizing. In
transaction BP you can find the field in the section Additional
Purchasing Control Data in the supplier subrange and plant data
(Additional Purchasing Data).
Option 2: Change the customizing in view cluster VC_TWVMO (with
transaction sm34).
Error message extract from SAP system. Copyright SAP SE.
CVIV_VAL011
- Subrange "&1" plant "&2": PROACT control prof "&3" not in TWVMO ?The SAP error message CVIV_VAL011 indicates that there is an issue with the PROACT control profile in relation to a specific subrange and plant. This error typically arises in the context of variant configuration and production planning, particularly when dealing with configurable materials.
Cause:
The error message CVIV_VAL011 is triggered when the system cannot find the specified PROACT control profile in the TWVMO table for the given subrange and plant. This can happen due to several reasons:
- Missing Control Profile: The specified control profile does not exist in the TWVMO table for the given plant and subrange.
- Incorrect Configuration: The configuration settings for the material or the control profile may not be set up correctly.
- Data Inconsistency: There may be inconsistencies in the data, such as missing entries or incorrect mappings between the control profile and the plant/subrange.
Solution:
To resolve the CVIV_VAL011 error, you can take the following steps:
Check TWVMO Table: Verify that the PROACT control profile specified in the error message exists in the TWVMO table for the given plant and subrange. You can do this by executing a transaction code like SE16 or SE11 to view the table contents.
Create or Update Control Profile: If the control profile is missing, you may need to create it or update the existing one. This can typically be done in the configuration settings for variant configuration or production planning.
Review Configuration Settings: Ensure that the configuration settings for the material are correct. Check the material master data and the configuration profiles to ensure they are properly linked.
Consult Documentation: Refer to SAP documentation or help resources for guidance on setting up PROACT control profiles and their relationship with plants and subranges.
Contact SAP Support: If you are unable to resolve the issue, consider reaching out to SAP support for assistance, especially if this is a production-critical issue.
Related Information:
By following these steps, you should be able to identify the root cause of the CVIV_VAL011 error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
CVIV_VAL010
Subrange "&1" plant "&2": Planning cycle "&3" not in T439G
What causes this issue? You cannot use value &V3& in the field Planning cycle (LFM2-LFRHY) because it is not defined in customizing table T43...
CVIV_VAL009
Subrange "&1" plant "&2": Planning cal. "&3" not in T439G
What causes this issue? You cannot use value &V3& in the field Planning cal. (Planning Calendar) (LFM2-MRPPP) because it is not defined in cu...
CVIV_VAL012
Subrange "&1" plant "&2": Rnding Profile "&3" not in RDPR
What causes this issue? You cannot use value &V3& in the field Rnding Profile (Rounding Profile) (LFM2-RDPRF) because it is not defined in cu...
CVIV_VAL014
The above incoterms error is in subrange "&1" plant "&2"
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.