Do you have any question about this error?
Message type: E = Error
Message class: CONV - Messages in Connection with the Converter
Message number: 213
Message text: Neither ConvPath.txt nor ConvPathAndMatrix.txt were created.
The following error occured when implementng a converter with
<LS>ConvServSamp</>:
No error was reported during conversion.
The first line of the file <LS>Error.txt</> is empty.
No file was created where the file name of the covnerted file is
located (ConvPath.txt or ConvPathAndMatrix.txt).
The file &V1&&V2&&V3&&V4& was not found.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
CONV213
- Neither ConvPath.txt nor ConvPathAndMatrix.txt were created. ?The SAP error message CONV213 indicates that the system was unable to create the files ConvPath.txt or ConvPathAndMatrix.txt during a conversion process. This error typically occurs in the context of data migration or system conversion activities, such as when using the SAP Software Update Manager (SUM) or during a system upgrade.
Causes:
- File System Permissions: The user or process executing the conversion may not have the necessary permissions to create files in the specified directory.
- Disk Space Issues: There may not be enough disk space available on the server to create the required files.
- Incorrect Configuration: The configuration settings for the conversion process may be incorrect, leading to the failure in file creation.
- Path Issues: The specified path for the output files may not exist or may be incorrectly defined in the configuration.
- Temporary Directory Issues: The temporary directory used by the conversion process may be full or not accessible.
Solutions:
- Check Permissions: Ensure that the user executing the conversion has the necessary permissions to write to the target directory. You may need to adjust the permissions or run the process as a user with higher privileges.
- Free Up Disk Space: Check the available disk space on the server and free up space if necessary. You can use tools like
df -h
on Unix/Linux systems to check disk usage.- Review Configuration: Verify the configuration settings for the conversion process. Ensure that all paths and parameters are correctly set.
- Validate Paths: Check that the paths specified for the output files exist and are accessible. If they do not exist, create the necessary directories.
- Check Temporary Directory: Ensure that the temporary directory used by the conversion process is accessible and has sufficient space. You may need to clean up old files or change the temporary directory settings.
Related Information:
If the issue persists after trying the above solutions, consider reaching out to SAP support for further assistance.
Get instant SAP help. Start your 7-day free trial now.
CONV212
Error message from converter: &1&2&3&4.
What causes this issue? An error occured while converting the original application file. The error is: &V1&&V2&&V3&&V4&am...
CONV211
The return value of the system command for starting the converter is &1
What causes this issue? The converter was started with the system command &V2& &V3& &V4&. An error occured and the return val...
CONV214
Error while reading file &1&2&3&4
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
CONV215
Error while reading file &1&2&3&4 ; Line too short
What causes this issue? Ths syntax requires that the file named have a line that is longer than the line read from the filed named.System Response T...
Click on this link to search all SAP messages.