Do you have any question about this error?
Stop googling SAP errors. Use our Free Essentials plan instead - no credit card needed. Start Now →
Message type: E = Error
Message class: CNVOM_UI_DEL - Messages for Deletion Monitor
Message number: 018
Message text: Invalid system type &1
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
CNVOM_UI_DEL018
- Invalid system type &1 ?The SAP error message CNVOM_UI_DEL018 with the description "Invalid system type &1" typically occurs in the context of data migration or conversion processes, particularly when using the SAP S/4HANA Migration Cockpit or similar tools. This error indicates that the system type being referenced is not recognized or is invalid for the operation being performed.
Cause:
- Incorrect System Type: The system type specified in the configuration or during the migration process does not match any of the expected values. This could be due to a typo or an incorrect setting in the migration cockpit.
- Configuration Issues: The system may not be properly configured to recognize the specified system type, possibly due to missing or incorrect entries in the relevant configuration tables.
- Version Compatibility: The error may arise if there is a mismatch between the version of the migration tool and the version of the source or target system.
Solution:
- Check Configuration: Verify the configuration settings in the migration cockpit or the relevant transaction. Ensure that the system type is correctly specified and matches the expected values.
- Review Documentation: Consult the SAP documentation for the migration tool you are using to ensure that you are using the correct system type and that it is supported.
- Update System Type: If you find that the system type is incorrect, update it to a valid type as per the documentation or the requirements of the migration process.
- Check for Updates: Ensure that your SAP system and migration tools are up to date. Sometimes, applying the latest patches or updates can resolve compatibility issues.
- Consult SAP Notes: Look for any relevant SAP Notes that might address this specific error. SAP Notes often provide solutions or workarounds for known issues.
- Contact SAP Support: If the issue persists after checking the above points, consider reaching out to SAP Support for further assistance.
Related Information:
By following these steps, you should be able to identify the cause of the error and implement a solution to resolve it.
Get instant SAP help. Sign up for our Free Essentials Plan.
CNVOM_UI_DEL017
Invalid preselection table &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
CNVOM_UI_DEL016
No successors found for selected task
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
CNVOM_UI_DEL019
Deletion monitor has already been opened in same session
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
CNVOM_UI_DEL020
Table count not started due to no analysis found; see long text
What causes this issue? Table records counting requires that an analysis must be assigned to the embedded specification.System Response How to fix th...
Click on this link to search all SAP messages.