Do you have any question about this error?
Message type: E = Error
Message class: CNV_10020 - Message class for package 10020
Message number: 773
Message text: &1 &2: Generation of a case structure not possible due to differ. lengths
For the generation of &V1& &V2&, a case structure is desired. This is
not possible because of different lengths in the source determination
object of the parent path (&V3&) and a sub path (&V4&).
The system automatically switches to the generation style "internal
table".
No user action is required.
&HINTS&
See the documentation of the <DS:DE.CNV_10020_GENER_STYLE>Generation
style</> for more information.
Error message extract from SAP system. Copyright SAP SE.
CNV_10020773
- &1 &2: Generation of a case structure not possible due to differ. lengths ?The SAP error message CNV_10020773 typically occurs during data migration or conversion processes, particularly when using the SAP S/4HANA Migration Cockpit or similar tools. This error indicates that there is an issue with the generation of a case structure due to differing lengths of data fields.
Cause:
The error is caused by a mismatch in the lengths of the fields being processed. Specifically, it can occur when:
To resolve this error, you can take the following steps:
Check Field Lengths: Review the field lengths in both the source and target systems. Ensure that the lengths match or that the target fields can accommodate the data from the source.
Data Mapping: Verify the data mapping configuration in the migration tool. Ensure that the mappings are correctly defined and that the data types are compatible.
Data Cleansing: If the source data contains values that exceed the target field lengths, consider cleansing the data. This may involve truncating values, converting data types, or modifying the data structure.
Adjust Target Structure: If feasible, adjust the target structure to accommodate the source data. This may involve increasing the field lengths in the target system.
Review Migration Settings: Check the settings and parameters used in the migration process. Ensure that they are correctly configured to handle the data being migrated.
Consult Documentation: Refer to SAP documentation or notes related to the specific migration tool you are using. There may be specific guidelines or known issues related to this error.
Testing: After making adjustments, perform a test migration with a smaller dataset to ensure that the changes resolve the issue before proceeding with the full migration.
By following these steps, you should be able to identify the root cause of the error and implement a solution to successfully complete the data migration process.
Get instant SAP help. Start your 7-day free trial now.
CNV_10020772
&1 &2: Generation of a case structure not possible due to sub path &3
What causes this issue? For the generation of &V1& &V2&, a case structure is desired. This is not possible because of the sub path &a...
CNV_10020771
&1 &2: &3 does not allow initial target determination values
What causes this issue? The determination result of &V3& is compared with the value space. By default, determination paths treat an initial t...
CNV_10020774
&1 &2: incorrect rule assignment for evaluation of nested component &3
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
CNV_10020775
&1: multiple passed parameters are assigned to rule parameter &2
What causes this issue? For the rule assigned to the component, the rule parameter &V2& is defined. For this rule parameter, the passed param...
Click on this link to search all SAP messages.