Do you have any question about this error?
Message type: E = Error
Message class: CNV - Conversion: Messages for Conversion Services (CNCC)
Message number: 472
Message text: The optimized cluster technique can not be used for table &
For table cluster &V1&, there is a conflict between the sequence
relationships of its dependent cluster tables.
The optimized cluster technique for table &V1& can not be used.
In case that performance problems are expected and you want to use the
optimized cluster technique for table &V1&, then contact SAP for
support.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
CNV472
- The optimized cluster technique can not be used for table & ?The SAP error message CNV472 indicates that the optimized cluster technique cannot be used for a specific table during a data migration or conversion process. This error typically arises in the context of SAP's data migration tools, such as the SAP S/4HANA Migration Cockpit or other data conversion scenarios.
Cause:
The error can occur due to several reasons, including:
Table Structure: The table in question may not be structured in a way that supports the optimized cluster technique. This could be due to the presence of certain data types, keys, or relationships that are incompatible with the optimized processing.
Data Volume: If the table contains a large volume of data, the optimized cluster technique may not be applicable, as it is designed for specific scenarios where data can be processed in a more efficient manner.
Configuration Issues: There may be configuration settings in the migration tool or the SAP system that prevent the use of the optimized cluster technique for that particular table.
Version Compatibility: The version of the SAP system or the migration tool being used may not support the optimized cluster technique for certain tables.
Solution:
To resolve the CNV472 error, consider the following steps:
Check Table Structure: Review the structure of the table mentioned in the error message. Ensure that it meets the requirements for the optimized cluster technique. You may need to consult SAP documentation or support for specific requirements.
Data Volume Management: If the table has a large volume of data, consider breaking it down into smaller batches for processing. This can help in managing the data more effectively and may allow the use of alternative processing techniques.
Review Migration Settings: Check the settings in the migration tool you are using. Ensure that all configurations are correct and that there are no restrictions preventing the use of the optimized cluster technique.
Consult SAP Notes: Look for relevant SAP Notes or Knowledge Base Articles (KBAs) that address this specific error. SAP frequently updates its documentation and may provide specific guidance or patches for known issues.
Contact SAP Support: If the issue persists after trying the above steps, consider reaching out to SAP Support for assistance. They can provide more detailed insights based on your specific system configuration and the context of the error.
Related Information:
By following these steps, you should be able to identify the cause of the CNV472 error and implement a suitable solution.
Get instant SAP help. Start your 7-day free trial now.
CNV471
There is a conflict between sequence relationships of tables
What causes this issue? There is a conflict between sequence relationships of tables defined in table CNVORDER and in table CNVTABLES. That means, t...
CNV470
No entry for table &1 in table CNVTABLES
What causes this issue? There is no entry for table &V1& in table CNVTABLES, for package &V2& and its dependent packages. It may ma...
CNV480
No entry for program &1 in table CNVSTATE
What causes this issue? There is no entry for program &V1& in table CNVSTATE, for package &V2& and its dependent packages. It may m...
CNV481
Phase &1 of predecessor &2 is different as phase &3 of successor &4
What causes this issue? Relationships between programs that belongs to different phases in CNVSTATE are defined. This is not feasibly, only relation...
Click on this link to search all SAP messages.