Message type: E = Error
Message class:  CNV - Conversion: Messages for Conversion Services (CNCC) 
Message number: 471
Message text: There is a conflict between sequence relationships of tables
There is a conflict between sequence relationships of tables defined in
table CNVORDER and in table CNVTABLES.  That means, the sequence
relationships of tables are not feasible,  because they contain at least
a cycle. The function module 'CNV_00001_CHECK_SEQUENCE' can be used to
identify the conflicts.
Please contact SAP for support.
Error message extract from SAP system. Copyright SAP SE.
The SAP error message CNV471 indicates that there is a conflict between sequence relationships of tables during a data migration or conversion process. This error typically arises in the context of SAP's data migration tools, such as the SAP S/4HANA Migration Cockpit or other data transfer processes.
Cause: The conflict usually occurs due to one of the following reasons: Inconsistent Data Relationships: The data in the source tables may have inconsistencies or conflicts in their relationships, such as foreign key constraints that are not being met. Incorrect Mapping: The mapping of fields between the source and target tables may not be correctly defined, leading to conflicts in how the data is sequenced or related. Missing Data: Required data in the source tables may be missing, which can lead to issues when trying to establish relationships in the target tables. Multiple Relationships: There may be multiple relationships defined between the same tables, which can create ambiguity in
 Get instant SAP help. Sign up for our Free Essentials Plan.
Get instant SAP help. Sign up for our Free Essentials Plan. 
CNV470 No entry for table &1 in table CNVTABLES
What causes this issue?  There is no entry for table &V1& in table CNVTABLES,  for package &V2& and its dependent packages.  It may ma...
CNV462 Program &1 for table &2 cannot run because of sequence relationships
What causes this issue?  Program &V1& cannot run at this point because not all programs whose tables are defined as predecessors of table &...
CNV472 The optimized cluster technique can not be used for table &
What causes this issue?  For table cluster &V1&, there is a conflict between the sequence relationships of its dependent cluster tables.System...
CNV480 No entry for program &1 in table CNVSTATE
What causes this issue?  There is no entry for program &V1& in table CNVSTATE,  for package &V2& and its dependent packages.  It may m...
Click on this link to search all SAP messages.