Do you have any question about this error?
Message type: E = Error
Message class: CM_CBESCOM_INB - Message Class for ESComXML Inbound Processing
Message number: 179
Message text: Exposure scenario header data &1 has incorrect specification type &2
The system has determined specification &V1& with the specification type
&V2& from the ESComXML file for the exposure scenario.
Exposure scenario header data must be assigned only specifications with
the specification type &V3&.
INCLUDE EHSPRC_ESCOM_INB_STOP OBJECT DOKU ID TX
Change specification &V1& in <DS:TRAN.CG02>specification management</>:
Change the following identifiers:
UUID (NUM ES_UUID)
Version date (NUM ES_DT_STMP)
If you no longer use specification &V1&, you can delete it.
INCLUDE EHSPRC_ESCOM_CONTACT OBJECT DOKU ID TX
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
CM_CBESCOM_INB179
- Exposure scenario header data &1 has incorrect specification type &2 ?The SAP error message CM_CBESCOM_INB179 indicates that there is an issue with the specification type in the exposure scenario header data. This error typically arises in the context of SAP's Environment, Health, and Safety (EHS) module, particularly when dealing with chemical substances and their exposure scenarios.
Cause:
The error message CM_CBESCOM_INB179 is triggered when the specification type defined in the exposure scenario header does not match the expected or valid specification types for the given context. This could be due to:
- Incorrect Configuration: The specification type may not be correctly configured in the system.
- Data Entry Error: There may be a typo or incorrect value entered in the specification type field.
- Missing Master Data: The specification type may not exist in the master data or may not be properly linked to the exposure scenario.
- Versioning Issues: If there are multiple versions of the exposure scenario, the wrong version may be referenced.
Solution:
To resolve this error, you can take the following steps:
Check Specification Type: Verify the specification type defined in the exposure scenario header. Ensure that it is a valid type recognized by the system.
Review Configuration: Check the configuration settings for specification types in the EHS module. Ensure that the specification type is correctly set up and linked to the relevant exposure scenarios.
Correct Data Entry: If the specification type was entered manually, double-check for any typos or incorrect values.
Master Data Validation: Ensure that the specification type exists in the master data and is properly maintained. You can do this by navigating to the relevant master data transaction in SAP.
Consult Documentation: Refer to SAP documentation or help files related to EHS and exposure scenarios for guidance on valid specification types.
Check for Updates: If you are using a specific version of SAP, ensure that you have the latest updates or patches applied, as these may resolve known issues.
Contact SAP Support: If the issue persists after checking the above points, consider reaching out to SAP support for further assistance.
Related Information:
By following these steps, you should be able to identify and resolve the issue related to the CM_CBESCOM_INB179 error message in SAP.
Get instant SAP help. Start your 7-day free trial now.
CM_CBESCOM_INB178
Consumer contributing scenario exists in system; &1 will be assigned
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
CM_CBESCOM_INB177
Consumer contributing scenario &1 will be created
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
CM_CBESCOM_INB180
Worker contributing scenario cannot be assigned uniquely
What causes this issue? The system has determined multiple <LS>Worker contributing scenarios</> with the identifier of the UUID (NUM CS_U...
CM_CBESCOM_INB181
Consumer contributing scenario cannot be assigned uniquely
What causes this issue? The system has determined multiple <LS>Consumer contributing scenarios </> with the identifier of the UUID (NUM C...
Click on this link to search all SAP messages.