Do you have any question about this error?
Message type: E = Error
Message class: CJ - Project master data and structure
Message number: 275
Message text: Hierarchy for &1 &2 cannot be &3 and &4 is not allowed
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
CJ275
- Hierarchy for &1 &2 cannot be &3 and &4 is not allowed ?The SAP error message CJ275 typically occurs in the context of project management and controlling, particularly when dealing with project hierarchies and structures in the Project System (PS) module. The error message indicates that there is an issue with the hierarchy structure of a project or a network.
Cause:
The error message "Hierarchy for &1 &2 cannot be &3 and &4 is not allowed" generally arises due to one of the following reasons:
Invalid Hierarchy Level: The system is trying to assign a project or network to a hierarchy level that is not allowed. For example, you might be trying to assign a lower-level project to a higher-level project incorrectly.
Incorrect Project Type: The project type or network type being used may not be compatible with the hierarchy structure defined in the system.
Missing Authorizations: The user may not have the necessary authorizations to perform the action on the specified project or network.
Configuration Issues: There may be configuration settings in the Project System that restrict certain types of hierarchies or relationships between projects and networks.
Solution:
To resolve the CJ275 error, you can take the following steps:
Check Hierarchy Structure: Review the hierarchy structure of the project or network you are trying to work with. Ensure that you are assigning it to the correct level and that it adheres to the defined hierarchy rules.
Verify Project Types: Ensure that the project or network types you are using are compatible with the hierarchy you are trying to create or modify.
Review Authorizations: Check if the user has the necessary authorizations to perform the action. If not, you may need to request additional permissions from your SAP security team.
Consult Configuration Settings: If you have access to the configuration settings, review the settings related to project hierarchies in the Project System. Ensure that they are set up correctly to allow the desired hierarchy structure.
Check for Dependencies: Sometimes, other projects or networks may have dependencies that affect the hierarchy. Ensure that there are no conflicting relationships.
Consult Documentation: Refer to SAP documentation or help resources for specific details about the error message and its context.
Related Information:
By following these steps, you should be able to identify the root cause of the CJ275 error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
CJ274
Cannot create asset under construction for a simulation WBS
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
CJ273
Simulation &1 &2 consists of partial trees. No transfer possible
What causes this issue? You transferred a simulation to a subtree and now want to transfer the entire simulation to an existing project. However, th...
CJ276
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
CJ277
Field Key &1 is not valid for the Project Definition.
What causes this issue? The field key cannot be used for the project definition.System Response The system issues an error message and will not allo...
Click on this link to search all SAP messages.