Do you have any question about this error?
Message type: E = Error
Message class: CFD_REGISTRY_CHECK - Custom Fields: Messages for Registry Check
Message number: 261
Message text: No FLX class could be found in your OData class hierarchy for &1
No FLX class could be found in your OData class hierarchy for OData
class <(>&<)>1.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Please check if you implemented the extensibility enabling in your OData
classes by calling the corresponding Extensibility API
IF_CFD_ODATA_RUNTIME directly. Otherwise you should generate a FLX class
via report CFD_CREATE_FLX_CLASS and add it in your OData class
hierarchy.
Further details can be found in the Adoption Guideline.
Error message extract from SAP system. Copyright SAP SE.
CFD_REGISTRY_CHECK261
- No FLX class could be found in your OData class hierarchy for &1 ?The SAP error message CFD_REGISTRY_CHECK261 indicates that the system is unable to find a Flexible (FLX) class in the OData class hierarchy for the specified entity type. This typically occurs when there is a misconfiguration or missing components in the OData service definition.
Cause:
- Missing FLX Class: The specified entity type does not have an associated FLX class defined in the OData service.
- Incorrect Configuration: The OData service might not be properly configured to include the necessary FLX classes.
- Transport Issues: If the OData service was recently transported from one system to another, the FLX classes may not have been included in the transport.
- Development Errors: There may be errors in the development of the OData service, such as incorrect annotations or missing implementations.
Solution:
Check OData Service Definition:
- Go to the OData service definition in the SAP Gateway Service Builder (transaction code SEGW).
- Ensure that the entity type in question has a corresponding FLX class defined.
Implement Missing FLX Class:
- If the FLX class is missing, you may need to implement it. This can involve creating a new class that extends the appropriate base class and implements the necessary methods.
Review Annotations:
- Check the annotations in your OData service to ensure that they are correctly defined and that they reference the correct FLX class.
Regenerate the OData Service:
- After making changes, regenerate the OData service to ensure that all components are correctly updated. This can be done in the Service Builder.
Transport Requests:
- If the issue arose after a transport, ensure that all necessary objects, including FLX classes, are included in the transport request.
Check for Errors in Implementation:
- Review the implementation of the OData service for any coding errors that might prevent the FLX class from being recognized.
Debugging:
- If the issue persists, consider debugging the OData service to trace where the error occurs and gather more information about the missing class.
Related Information:
By following these steps, you should be able to identify and resolve the issue related to the CFD_REGISTRY_CHECK261 error message in your SAP system.
Get instant SAP help. Start your 7-day free trial now.
CFD_REGISTRY_CHECK260
FLX class &1 is outdated; Regenerate via report CFD_CREATE_FLX_CLASS
What causes this issue? In your OData class hierarchy you use the FLX class <(>&<)>1 for runtime handling of custom fields. Unfortuna...
CFD_REGISTRY_CHECK259
Entered DDIC structure &1 not unique; used also in Model &2 for Entity &3
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
CFD_REGISTRY_CHECK262
New Redirect Views currently not registerable; contact Extensibility team
What causes this issue? Currently registration of Redirect Views to support extensibility is not possible as the following issues are not yet clarifi...
CFD_REGISTRY_CHECK263
DB table &1 of Incl. &2 has Redirect View &3; contact Extensibility team
What causes this issue? Currently registration of Redirect Views to support extensibility is not possible as the following issues are not yet clarifi...
Click on this link to search all SAP messages.