Do you have any question about this error?
Message type: E = Error
Message class: CFD_REGISTRY_CHECK - Custom Fields: Messages for Registry Check
Message number: 219
Message text: Missing branch position &1 of branch &2 with direct union suffix &3.
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
CFD_REGISTRY_CHECK219
- Missing branch position &1 of branch &2 with direct union suffix &3. ?The SAP error message CFD_REGISTRY_CHECK219 indicates that there is a missing branch position in the context of a direct union suffix. This error typically arises in the context of the SAP Convergent Charging (SAP CC) or similar modules where complex charge calculations and configurations are involved.
Cause:
- Configuration Issues: The error often occurs due to misconfiguration in the charging logic or the branch definitions in the SAP CC system. Specifically, it indicates that the system is unable to find a specified branch position that is expected to exist.
- Data Integrity Problems: There may be inconsistencies or missing data in the configuration tables that define the branches and their relationships.
- Incorrect Union Suffix: The direct union suffix specified in the error message may not correspond to any existing branch position, leading to this error.
Solution:
- Check Configuration: Review the configuration settings for the branches in the SAP CC system. Ensure that all required branch positions are defined and correctly linked.
- Validate Union Suffix: Verify that the direct union suffix specified in the error message is valid and corresponds to an existing branch position. If it is incorrect, update it to the correct value.
- Data Consistency Check: Run consistency checks on the configuration data to identify any missing or inconsistent entries. This may involve checking the relevant tables in the database.
- Recreate Missing Branch: If a branch position is indeed missing, you may need to recreate it in the system, ensuring that it is properly configured and linked to the relevant branches.
- Consult Documentation: Refer to the SAP documentation for Convergent Charging or the specific module you are working with for detailed guidance on branch configurations and troubleshooting steps.
Related Information:
By following these steps, you should be able to identify the root cause of the CFD_REGISTRY_CHECK219 error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
CFD_REGISTRY_CHECK218
Position of direct union suffix &1 is different in branch &2 and &3.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
CFD_REGISTRY_CHECK217
Underlying view is different in entry &1 and &2 of branch &3.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
CFD_REGISTRY_CHECK220
Description fields not supported for CDS view &1 (due to group by clause)
What causes this issue? Description fields are not supported in consumption view <(>&<)>1 (Annotation @VDM.viewType: #CONSUMPTION), w...
CFD_REGISTRY_CHECK221
Usage of DDIC suffix &1 in structure &2 for Include &3 cause DDIC errors
What causes this issue? Usage of DDIC suffixes for Extensibility Includes is only possible if the longest possible field name does not exceed 30 char...
Click on this link to search all SAP messages.