Do you have any question about this error?
Message type: E = Error
Message class: BRAIN -
Message number: 236
Message text: Reading of aggregate part &2 deactivated
In delta pair class &V1&, reading of aggregate part &V2& was switched
off.
Delta part &V3& is read fully.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
BRAIN236
- Reading of aggregate part &2 deactivated ?The SAP error message BRAIN236, which states "Reading of aggregate part &2 deactivated," typically occurs in the context of SAP BW (Business Warehouse) when there is an issue with the aggregate data in the InfoCube. This error indicates that the system has deactivated the reading of a specific aggregate due to various reasons, such as inconsistencies or issues with the data.
Causes:
- Data Inconsistencies: The aggregate may have inconsistencies or errors in the underlying data that prevent it from being read.
- Changes in InfoObjects: If there have been changes to the InfoObjects that are part of the aggregate, it may lead to deactivation.
- Missing or Incomplete Data: If the data required for the aggregate is missing or incomplete, the system may deactivate it.
- Performance Issues: Sometimes, aggregates are deactivated to improve performance if they are not being used or if they are causing performance bottlenecks.
- Manual Deactivation: An administrator may have manually deactivated the aggregate for maintenance or other reasons.
Solutions:
- Check Data Consistency: Use transaction codes like RSA1 (Data Warehousing Workbench) to check the consistency of the data in the InfoCube and the aggregates.
- Rebuild the Aggregate: If the aggregate is corrupted or has issues, you may need to rebuild it. This can be done by using the "Manage Aggregates" option in the Data Warehousing Workbench.
- Analyze InfoObjects: Review any recent changes made to InfoObjects that are part of the aggregate. If changes were made, consider adjusting the aggregate accordingly.
- Check for Missing Data: Ensure that all necessary data is loaded into the InfoCube. If data is missing, perform the necessary data loads.
- Re-activate the Aggregate: If the aggregate was manually deactivated, you can reactivate it through the Data Warehousing Workbench.
- Consult Logs: Check the system logs for any additional error messages or warnings that may provide more context about the issue.
Related Information:
If the problem persists after trying the above solutions, it may be beneficial to consult with your SAP Basis or BW team for further investigation and support.
Get instant SAP help. Start your 7-day free trial now.
BRAIN235
For &1, aggregate part &2 must have a fully-fledged delta method
What causes this issue? Deltacache class &V3& of InfoProvider &V2& is only suitable as a delta part of a delta pair. In delta pair cl...
BRAIN234
Property 'All Basic Key Figures Input Ready' is not permitted for &1
What causes this issue? The InfoProvider is an aggregation level or contains the aggregation level &V1& as an InfoProvider contained in the M...
BRAIN237
Reading of delta part &3 deactivated
What causes this issue? In delta pair class &V1& reading of delta part &V3& has been deactivated.System Response Only the aggregate ...
BRAIN238
Reading of delta pair &2 &3 was switched off
What causes this issue? In delta pair class &V1&, reading of aggregate part &V2& and of delta part &V3& was switched off.Syst...
Click on this link to search all SAP messages.