Do you have any question about this error?
Message type: E = Error
Message class: BRAIN -
Message number: 235
Message text: For &1, aggregate part &2 must have a fully-fledged delta method
Deltacache class &V3& of InfoProvider &V2& is only suitable as a delta
part of a delta pair. In delta pair class &V1& it should be used as an
aggregation part.
The MultiProvider cannot be used in this way.
Change classes &V1& and &V3& as well as the corresponding entries in
table RSDCUBEMULTI.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
BRAIN235
- For &1, aggregate part &2 must have a fully-fledged delta method ?The SAP error message BRAIN235 indicates that there is an issue with the delta method configuration for an aggregate in the SAP BW (Business Warehouse) system. Specifically, it suggests that the aggregate part you are trying to work with does not have a fully-fledged delta method defined, which is necessary for the system to process data changes correctly.
Cause:
- Missing Delta Method: The aggregate part specified in the error message does not have a delta method defined. Delta methods are essential for tracking changes in data and ensuring that the aggregate can be updated efficiently.
- Incorrect Configuration: The configuration of the InfoObject or the aggregate may be incomplete or incorrect, leading to the absence of a valid delta method.
- Data Source Issues: The data source from which the aggregate is pulling data may not be set up to support delta processing.
Solution:
Define a Delta Method:
- Go to the Data Warehousing Workbench (transaction RSA1).
- Navigate to the InfoProvider that contains the aggregate.
- Check the settings for the aggregate and ensure that a delta method is defined.
- If it is missing, you may need to create or configure a delta method for the aggregate.
Check Aggregate Settings:
- Ensure that the aggregate is correctly configured to use the appropriate data source.
- Verify that the InfoObject associated with the aggregate has the correct settings for delta processing.
Rebuild the Aggregate:
- If the configuration appears correct but the error persists, consider rebuilding the aggregate. This can sometimes resolve issues related to configuration inconsistencies.
Consult Documentation:
- Review SAP documentation or notes related to aggregates and delta methods for any specific requirements or additional troubleshooting steps.
Check for SAP Notes:
- Look for any relevant SAP Notes that may address this specific error message or provide guidance on delta method configuration.
Related Information:
If you continue to experience issues after following these steps, consider reaching out to your SAP support team or consulting with an SAP BW expert for further assistance.
Get instant SAP help. Start your 7-day free trial now.
BRAIN234
Property 'All Basic Key Figures Input Ready' is not permitted for &1
What causes this issue? The InfoProvider is an aggregation level or contains the aggregation level &V1& as an InfoProvider contained in the M...
BRAIN233
Aggregate part &1 must not be a real-time InfoCube
What causes this issue? InfoCube &V1& is entered as the aggregate pair of a delta pair. This is not possible for real-time InfoCubes.System R...
BRAIN236
Reading of aggregate part &2 deactivated
What causes this issue? In delta pair class &V1&, reading of aggregate part &V2& was switched off.System Response Delta part &V3...
BRAIN237
Reading of delta part &3 deactivated
What causes this issue? In delta pair class &V1& reading of delta part &V3& has been deactivated.System Response Only the aggregate ...
Click on this link to search all SAP messages.