Do you have any question about this error?
Message type: E = Error
Message class: BIL - General billing
Message number: 104
Message text: Quantity determ.procedure &1 is not admissible for dynamic period control
You attempted to perform billing using dynamic period control (DPC).
During the period &v2& - &v3&, the quantity determination procedure <LS>
Quantity Determination During Meter Reading</> is active. The assigned
rate category is &v4& .
It is not possible to use the quantity determination procedure selected
in conjunction with dynamic period control.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
INCLUDE ISU_VERARB OBJECT DOKU ID TXSelect a different rate category or a different quantity determination
procedure.
Error message extract from SAP system. Copyright SAP SE.
BIL104
- Quantity determ.procedure &1 is not admissible for dynamic period control ?The SAP error message BIL104, which states "Quantity determination procedure &1 is not admissible for dynamic period control," typically occurs in the context of billing and invoicing processes within SAP. This error indicates that the quantity determination procedure specified is not compatible with the dynamic period control settings in the system.
Cause:
- Incompatible Quantity Determination Procedure: The quantity determination procedure defined in the billing document or configuration does not support dynamic period control. This can happen if the procedure is set up for static period control or if it is not configured correctly.
- Configuration Issues: There may be a misconfiguration in the billing settings or the quantity determination procedure itself.
- Master Data Issues: The master data related to the billing document (like customer master, material master, etc.) may not be set up correctly to support the required quantity determination procedure.
Solution:
Check Configuration:
- Go to the configuration settings for billing in SAP (Transaction SPRO).
- Navigate to Sales and Distribution > Billing > Billing Documents > Define Quantity Determination Procedures.
- Verify that the quantity determination procedure you are using is compatible with dynamic period control.
Adjust Quantity Determination Procedure:
- If the procedure is not compatible, you may need to either change the procedure to one that is compatible with dynamic period control or adjust the settings to allow for the use of the current procedure.
Review Dynamic Period Control Settings:
- Check the settings for dynamic period control in the billing configuration. Ensure that the settings align with the requirements of your business processes.
Master Data Review:
- Review the relevant master data (customer, material, etc.) to ensure that all necessary fields and settings are correctly configured.
Consult Documentation:
- Refer to SAP documentation or help resources for specific details on the quantity determination procedures and their compatibility with dynamic period control.
Testing:
- After making changes, perform testing to ensure that the error no longer occurs and that the billing process works as expected.
Related Information:
If the issue persists after following these steps, it may be beneficial to consult with an SAP expert or your organization's SAP support team for further assistance.
Get instant SAP help. Start your 7-day free trial now.
BIL103
References in meter reading doc. &1 date &2 / &3 date &4 are inconsistent
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
BIL102
No referencing document found for meter reading document &1 date &2
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
BIL105
Quantity determination proced.&1 is not admissible for demand registers
What causes this issue? A technical error has occurred. The quantity determination procedure &v1& is allocated to the demand register &v2...
BIL106
Dynam.period control not admissible for quantity determination proc.&1
What causes this issue? The rate category &v2& uses dynamic period control (DPC). The installation contains devices with quantity determinati...
Click on this link to search all SAP messages.