Do you have any question about this error?
Message type: E = Error
Message class: AJ - Billing program
Message number: 484
Message text: Energy feeding volumes for &1 cal. val. district incompletely maintained
Gas billing uses the energy feeding volumes maintained here when no
other volumes could be determined. Therefore, you must maintain an
energy feeding volume here for each calorific value district and month.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
AJ484
- Energy feeding volumes for &1 cal. val. district incompletely maintained ?The SAP error message AJ484 indicates that there are incomplete entries for energy feeding volumes in the specified calculation value for a district. This error typically arises in the context of energy management or utility billing within SAP, particularly in modules related to energy data management (like IS-U).
Cause:
The error message AJ484 is triggered when:
- Incomplete Data: The energy feeding volumes for a specific calculation value (e.g., a district or a specific meter) have not been fully maintained. This could mean that required fields are missing or that the data has not been entered for all relevant periods.
- Configuration Issues: There may be configuration settings that are not properly set up, leading to incomplete data entries.
- Data Entry Errors: Manual data entry errors or omissions can lead to this message being displayed.
Solution:
To resolve the AJ484 error, you can take the following steps:
Check Data Entries:
- Navigate to the relevant transaction or report where the energy feeding volumes are maintained.
- Verify that all required fields for the calculation value are filled in completely. This includes checking for any missing entries for specific periods.
Review Configuration:
- Ensure that the configuration settings for energy management and billing are correctly set up. This may involve checking the settings in the IS-U module.
- Consult with your SAP Basis or configuration team if you suspect that there are issues with the setup.
Data Maintenance:
- If you find that data is missing, enter the required energy feeding volumes for the relevant periods.
- Ensure that the data is consistent and accurate to avoid future errors.
Consult Documentation:
- Refer to SAP documentation or help files related to energy management and billing for specific guidance on maintaining energy feeding volumes.
Testing:
- After making the necessary corrections, test the process again to ensure that the error message no longer appears.
Seek Support:
- If the issue persists after checking the above points, consider reaching out to SAP support or your internal IT team for further assistance.
Related Information:
By following these steps, you should be able to identify and resolve the cause of the AJ484 error message in SAP.
Get instant SAP help. Start your 7-day free trial now.
AJ483
Enter a container for &1 installation, &2 operand
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
AJ482
No entries in &2 table for &1 calorific value district
What causes this issue? Table &v2& does not contain any energy feeding volumes for calorific value district &v1&. This information is...
AJ485
Energy feeding vols for spec. cal. val. districts completely maintained
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
AJ486
&1 is not permitted as control for advance billing in &2 step
What causes this issue? You used value &V1& in step &V2& for <DS:DE.ADVCONTROL>control of billing in advance</>. This is ...
Click on this link to search all SAP messages.