Do you have any question about this error?
Message type: E = Error
Message class: AJ - Billing program
Message number: 241
Message text: Device &1 (logical register &2) period &3-&4: error reading P_X_ZW
An internal error occurred when reading P_X_IZW in routine
VCF_CVOL_MVOL of include LEA54F06. Specifically, the number of places
before the decimal point cannot be determined for the operating volume
meter, however, this is required to deal with a meter overflow in the
operating volume meter.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Please contact SAP.
Error message extract from SAP system. Copyright SAP SE.
AJ241
- Device &1 (logical register &2) period &3-&4: error reading P_X_ZW ?The SAP error message AJ241 typically relates to issues with reading data from a logical register in the context of device management or meter reading. The error message indicates that there was a problem reading the data for a specific period from a logical register associated with a device.
Cause:
- Data Availability: The data for the specified period may not be available in the system. This could be due to missing data entries or incomplete data uploads.
- Configuration Issues: There may be configuration issues with the logical register or the device itself, leading to an inability to read the required data.
- Technical Issues: There could be technical issues such as connectivity problems with the device, or issues with the underlying database or data model.
- Authorization Issues: The user or process attempting to read the data may not have the necessary authorizations to access the logical register.
Solution:
- Check Data Availability: Verify if the data for the specified period exists in the system. You can do this by checking the relevant tables or using transaction codes related to meter reading or device management.
- Review Configuration: Ensure that the logical register and device configurations are correct. Check if the logical register is properly assigned to the device and that all necessary parameters are set.
- Technical Troubleshooting: Investigate any technical issues that may be affecting the reading process. This could involve checking network connections, database integrity, or system logs for errors.
- Authorization Check: Ensure that the user or process has the necessary permissions to access the logical register. You may need to review user roles and authorizations in the SAP system.
- Consult Documentation: Refer to SAP documentation or support notes related to the specific error message for additional troubleshooting steps or patches that may resolve the issue.
Related Information:
EL31
(Display Meter Reading Document) or EL30
(Display Device) to help diagnose the issue.By following these steps, you should be able to identify the cause of the error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
AJ240
Error in communication processing
What causes this issue? An error occurred in function module ISU_PREPARE_USAGE_INFO_REV, which is responsible for communication processing in the bil...
AJ239
Value not permissible for a month: &1
What causes this issue? The number of months you specified (&v1&) is not between 1 and 12.System Response Processing is canceled.How to fix ...
AJ242
Dev. &1 reg. &2 per. &3-&4: no VCF (oper.vol. meter shows zero consumpt.)
What causes this issue? The register requires a gas procedure whose volume correction factor component is calculated using a special procedure that u...
AJ243
Line item type &1 does not exist
What causes this issue? You did not enter document line type &1 in customizing for the franchise fee. Please maintain the table <LS>Procedu...
Click on this link to search all SAP messages.