Do you have any question about this error?
Message type: E = Error
Message class: AJ - Billing program
Message number: 194
Message text: Device &1 register &2 period &3-&4: calorific value district missing
A volume correction factor procedure that requires calculation of
compressibility and/or supercompressibility though a user exit is
active for the specified register. To do this, the information for the
calorific value district must be complete in the installation structure
history. In this case, however, the data could not be determined
completely.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Please check the calorific value district history and add any missing
intervals. If you cannot find any gaps, an internal error may have
occurred. In this case, contact SAP.
Error message extract from SAP system. Copyright SAP SE.
AJ194
- Device &1 register &2 period &3-&4: calorific value district missing ?The SAP error message AJ194 indicates that there is a missing calorific value for a specific district in the context of energy management or utility billing. This error typically arises in the SAP IS-U (Industry Solution for Utilities) module, particularly when dealing with energy data such as gas or district heating.
Cause:
The error message AJ194 is triggered when the system attempts to process data related to a specific device (e.g., a meter) and finds that the calorific value for the specified district is not available for the given period. The calorific value is essential for calculating energy consumption and billing accurately.
Solution:
To resolve this error, you can take the following steps:
Check Calorific Value Data:
- Navigate to the relevant transaction in SAP (e.g., transaction code
EAM
orIS-U
related transactions) to check if the calorific value for the specified district is maintained in the system.- Ensure that the calorific value is defined for the required period (from period &3 to period &4).
Maintain Calorific Value:
- If the calorific value is missing, you will need to enter it. This can typically be done in the master data for the district or in the relevant configuration settings.
- Use transaction codes like
EEDM
(for maintaining energy data) orEEDC
(for maintaining calorific values) to input the necessary data.Review Configuration:
- Check the configuration settings for the district heating or gas supply to ensure that all necessary parameters, including calorific values, are correctly set up.
- Ensure that the relevant master data for the district is complete and accurate.
Data Consistency:
- Verify that there are no inconsistencies in the data that could lead to this error. This includes checking for any missing or incorrect entries in related tables.
Consult Documentation:
- Refer to SAP documentation or help resources for specific guidance on maintaining calorific values and resolving related errors.
Contact Support:
- If the issue persists after checking and maintaining the necessary data, consider reaching out to your SAP support team or consulting with an SAP expert for further assistance.
Related Information:
Transaction Codes:
EEDM
- Energy Data ManagementEEDC
- Calorific Value MaintenanceEAM
- Enterprise Asset Management (for checking device-related data)Tables:
EEDC
(Calorific Values) or EEDM
(Energy Data Management).Documentation:
By following these steps, you should be able to identify the cause of the error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
AJ193
A rate determination already exists for rate type &1 and rate category &2
What causes this issue? You attempted to define a rate determination for rate type &v1& and rate category &v2&, however, a rate deter...
AJ192
A rate determination does not exist for rate type &1 and rate category &2
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
AJ195
Device &1 reg. &2 period &3-&4: compressibility via user exit incorrect
What causes this issue? A volume correction factor procedure that requires calculation of compressibility and/or supercompressibility through user ex...
AJ196
Device &1 reg. &2 period &3-&4: compressibility from user exit missing
What causes this issue? A volume correction factor procedure that requires calculation of compressibility and/or supercompressibility through user ex...
Click on this link to search all SAP messages.