Do you have any question about this error?
Message type: E = Error
Message class: AH - IS-U billing (master data)
Message number: 588
Message text: Device &1 reg. &2 gas proc. &3 comparison &4: data inconsistency
An internal error has occurred. The system could not compare data due
to inconsistent time slices. You can find the specific table access in
the message supplement (double-click the error message in the log).
INCLUDE ISU_SAP OBJECT DOKU ID TX
Error message extract from SAP system. Copyright SAP SE.
AH588
- Device &1 reg. &2 gas proc. &3 comparison &4: data inconsistency ?The SAP error message AH588 indicates a data inconsistency related to a device and its associated parameters in the context of gas processing. This error typically arises in the SAP IS-Oil module, particularly when dealing with gas processing and measurement data.
Cause:
The error message AH588 can be triggered by several factors, including:
- Data Inconsistency: There may be discrepancies between the data stored in different tables or records related to the device, registration, or processing parameters.
- Configuration Issues: Incorrect configuration of the device or its parameters in the system can lead to inconsistencies.
- Missing Data: Required data for the device or its processing might be missing or incorrectly entered.
- System Errors: Bugs or issues within the SAP system itself can sometimes lead to unexpected inconsistencies.
Solution:
To resolve the AH588 error, you can follow these steps:
Check Device Configuration: Verify the configuration of the device in question. Ensure that all necessary parameters are correctly set up and consistent across the relevant tables.
Data Validation: Review the data associated with the device, registration, and processing. Look for any discrepancies or missing entries that could be causing the inconsistency.
Transaction Logs: Check transaction logs for any recent changes made to the device or its parameters that might have led to the inconsistency.
Consistency Check: Use SAP tools or reports to perform a consistency check on the relevant data. This can help identify specific areas where the data is inconsistent.
Consult Documentation: Refer to SAP documentation or notes related to the AH588 error for any specific guidance or patches that may address the issue.
Contact SAP Support: If the issue persists after performing the above checks, consider reaching out to SAP support for further assistance. They may provide insights or solutions based on the specific context of your system.
Related Information:
By following these steps, you should be able to identify and resolve the underlying cause of the AH588 error message in your SAP system.
Get instant SAP help. Start your 7-day free trial now.
AH587
Device &1 reg. &2 VCF proc. &3: no fixed volume correction factor in &4
What causes this issue? No fixed volume correction factor could be determined for the specified device/register via the access described.System Respo...
AH586
Not poss. to determine fixed gas law deviation factors for period &1 - &2
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
AH589
Errors have occurred in rate determination
What causes this issue? Errors have occurred in the rate determination for installation &v1&.System Response The system issues an error mess...
AH590
Dev. &1 reg. &2 VCF proc. &3: reg. relat. ZZ cannot be billed presently
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.