Do you have any question about this error?
Message type: E = Error
Message class: AH - IS-U billing (master data)
Message number: 092
Message text: General control indicators are partially ignored in special procedure
If you choose one of the procedures "Reg. rel. ZZ", "Reg. rel. ZE",
"Fixed VCF" or "Reg. VCF", then not all of the general control
indicators are taken into account (e.g. fixed temperature, averaging
type, average from, air pressure, gas law deviation factor correction).
Only the "Reg. rel. ZZ" procedure or the "Fixed VCF" procedure combined
with the control for the gas law deviation factor billing - i.e. gas
law deviation factor and gas law deviation factor correction - is taken
into account when the actual gas factors are calculated, e.g. in
billing.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
INCLUDE ISU_KORR OBJECT DOKU ID TX
Error message extract from SAP system. Copyright SAP SE.
AH092
- General control indicators are partially ignored in special procedure ?The SAP error message AH092, which states "General control indicators are partially ignored in special procedure," typically occurs in the context of financial accounting and controlling, particularly when dealing with special procedures like the "Special Ledger" or "Special Purpose Ledger."
Cause:
This error message is generally triggered when there are inconsistencies or conflicts between the general control indicators set in the system and the requirements of the special procedure being executed. The general control indicators are settings that determine how certain transactions are processed, and when a special procedure is in place, some of these indicators may not be applicable or may be overridden.
Possible Causes Include:
- Incompatible Settings: The general control indicators set for a particular transaction or document may not be compatible with the special procedure being used.
- Missing Configuration: The configuration for the special procedure may not be complete or may not align with the general control indicators.
- Transaction Type Issues: The transaction type being processed may not support the general control indicators in the context of the special procedure.
Solution:
To resolve the AH092 error, consider the following steps:
Review Configuration:
- Check the configuration settings for both the general control indicators and the special procedure. Ensure that they are compatible and correctly set up.
- Navigate to the relevant configuration areas in SAP (e.g., SPRO) and verify the settings for the special ledger or special purpose ledger.
Adjust Control Indicators:
- If certain control indicators are not applicable for the special procedure, consider adjusting them or using alternative indicators that are compatible.
Consult Documentation:
- Review SAP documentation or notes related to the specific special procedure you are using. There may be specific guidelines or recommendations for handling control indicators.
Test Transactions:
- Conduct test transactions to see if the error persists. This can help identify if the issue is with specific transaction types or configurations.
Seek Expert Help:
- If the issue remains unresolved, consider reaching out to your SAP support team or consulting with an SAP expert who can provide deeper insights into the configuration and potential conflicts.
Related Information:
By following these steps, you should be able to identify the root cause of the AH092 error and implement a suitable solution.
Get instant SAP help. Start your 7-day free trial now.
AH091
Only choose usage type if "fixed volume correction factor" is used
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
AH090
Rate type &1 already exists
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
AH093
Gas law deviation factor 01 only possible for temp./pressure billing
What causes this issue? The gas law deviation factor can only be determined using pressure and temperature if the temperature is calculated in the vo...
AH094
Maintain temperature component
What causes this issue? If you do not use a special procedure, you must also maintain the control fields for the temperature component (select the &l...
Click on this link to search all SAP messages.