Message type: E = Error
Message class: 8B - Localization (Brazil)
Message number: 706
Message text: Screen control reference &1 is used for NF-e and CT-e
The system uses the screen control reference both for NF-e as well as
for CT-e.
The screen control reference can only be assigned to one model.
Conversion is not possible.
Change the assignment in J_1BAL, so that the screen control reference is
only used by one model. Afterwards execute the XPRA run again.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
8B706
- Screen control reference &1 is used for NF-e and CT-e ?The SAP error message 8B706 indicates that there is an issue with the screen control reference being used for NF-e (Nota Fiscal Eletrônica) and CT-e (Conhecimento de Transporte Eletrônico). This error typically arises in the context of electronic invoicing in Brazil, where specific configurations and settings are required for the proper handling of these documents.
Cause: The error message 8B706 usually occurs due to one of the following reasons: Incorrect Screen Control Reference: The screen control reference specified in the configuration does not match the expected values for NF-e or CT-e processing. Missing Configuration: The necessary configuration for NF-e or CT-e is not set up correctly in the SAP system. Version Mismatch: The version of the SAP system or the add-ons related to NF-e/CT-e may not be compatible or properly updated. Authorization Issues: The user may not have the necessary authorizations to access or process NF-e or CT-e documents.
Solution: To resolve the error message 8B706, you can
Get instant SAP help. Sign up for our Free Essentials Plan.
8B705
Screen control reference &1 in J_1BAL: &2 changed to &3
What causes this issue? The screen control reference was continued under another number. The new number is used in table J_1BAL.System Response The ...
8B704
Screen control reference &1 in J_1BAM is converted to &2
What causes this issue? The screen control reference is not an entry supplied by SAP.System Response The conversion is only possible in the customer...
8B707
Screen control reference &1 was not converted
What causes this issue? The screen control reference is not used and is therefore not converted by the system.System Response The system does not co...
8B708
Report &1: &2
What causes this issue? Status messageSystem Response The system issues an error message and will not allow you to continue with this transaction un...
Click on this link to search all SAP messages.