Do you have any question about this error?
Message type: E = Error
Message class: 8B - Localization (Brazil)
Message number: 707
Message text: Screen control reference &1 was not converted
The screen control reference is not used and is therefore not converted
by the system.
The system does not convert the screen control group.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
8B707
- Screen control reference &1 was not converted ?The SAP error message 8B707 ("Screen control reference &1 was not converted") typically occurs during the execution of a transaction or program that involves screen control elements, such as dynpros (dynamic programs) or screen variants. This error indicates that the system encountered a screen control reference that it could not convert or recognize.
Causes:
- Missing or Incompatible Screen Elements: The screen control reference may point to a screen element that does not exist or is not compatible with the current version of the program or transaction.
- Transport Issues: If the program or screen was transported from one system to another (e.g., from development to production), there may be inconsistencies or missing objects in the target system.
- Custom Development: If there are custom screens or modifications, they may not have been properly implemented or activated.
- Version Mismatch: The error can occur if there are discrepancies between the versions of the SAP system components involved.
Solutions:
- Check Screen Control References: Verify that the screen control reference mentioned in the error message exists and is correctly defined in the program or transaction.
- Transport Consistency: Ensure that all necessary objects related to the screen control reference have been transported correctly. Check for any missing components in the target system.
- Activate/Regenerate Screens: If the screen is custom or modified, try to activate or regenerate the screen in the Screen Painter (SE80 or SE41).
- Debugging: Use the debugger to trace the program execution and identify where the error occurs. This can provide insights into what is causing the screen control reference to fail.
- Check for Notes: Look for SAP Notes related to this error message. Sometimes, SAP releases notes that provide fixes or workarounds for specific issues.
- Consult Documentation: Review the documentation for the program or transaction to ensure that all prerequisites and configurations are met.
Related Information:
By following these steps, you should be able to diagnose and resolve the error message 8B707 in your SAP environment.
Get instant SAP help. Start your 7-day free trial now.
8B706
Screen control reference &1 is used for NF-e and CT-e
What causes this issue? The system uses the screen control reference both for NF-e as well as for CT-e.System Response The screen control reference ...
8B705
Screen control reference &1 in J_1BAL: &2 changed to &3
What causes this issue? The screen control reference was continued under another number. The new number is used in table J_1BAL.System Response The ...
8B708
Report &1: &2
What causes this issue? Status messageSystem Response The system issues an error message and will not allow you to continue with this transaction un...
8B709
Parameter &1 and &2 screen control reference &3 are not the same
What causes this issue? SAP has merged the parameter groups from J_1BAE in J_1BAEH or in J_1BAEIT. However, the parameters in <(>&<)>...
Click on this link to search all SAP messages.