Do you have any question about this error?
Message type: E = Error
Message class: 6P - Messages for planned independent requirements (Appl.area 60)
Message number: 482
Message text: BOM explosion number & is not active
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
6P482
- BOM explosion number & is not active ?The SAP error message "6P482 BOM explosion number & is not active" typically relates to issues with Bill of Materials (BOM) in the SAP system. This error indicates that the specified BOM explosion number is not active, which means that the system cannot process the BOM for the specified material or configuration.
Cause:
- Inactive BOM: The BOM explosion number may refer to a BOM that is not currently active in the system. This can happen if the BOM has been deleted, not created, or is in a status that does not allow it to be used.
- Incorrect Configuration: The configuration settings for the material may not be set up correctly, leading to the system not being able to find an active BOM.
- Versioning Issues: If there are multiple versions of a BOM, the system may be trying to access a version that is not active.
- Plant-Specific Issues: The BOM may be plant-specific, and the plant in question may not have an active BOM for the material.
Solution:
- Check BOM Status: Verify the status of the BOM in the system. You can do this by using transaction code
CS03
(Display BOM) to check if the BOM exists and is active.- Activate BOM: If the BOM is inactive, you may need to activate it. This can be done using transaction code
CS02
(Change BOM) to set the BOM to active.- Create BOM: If the BOM does not exist, you may need to create it using transaction code
CS01
(Create BOM).- Check Configuration: Ensure that the configuration settings for the material are correct and that the correct BOM is being referenced.
- Review Plant Assignment: Make sure that the BOM is assigned to the correct plant and that the plant is active in the system.
- Check for Versioning: If there are multiple versions of the BOM, ensure that the correct version is being used and that it is active.
Related Information:
CS01
: Create BOMCS02
: Change BOMCS03
: Display BOMCS11
: Create BOM for a materialCS12
: Display BOM for a materialIf the issue persists after checking these aspects, it may be necessary to consult with your SAP support team or a functional consultant who specializes in BOM and material management.
Get instant SAP help. Start your 7-day free trial now.
6P481
Date lies in the planning time fence ( & - & )
What causes this issue? It is specified in Customizing for demand management, that a warning is issued when changes are made within the planning time...
6P480
New date lies in the planning time fence
What causes this issue? It is specified in Customizing for demand management, that a warning is issued when changes are made within the planning time...
6P483
BOM explosion number & is only valid in plant &
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
6P484
BOM explosion number & is only valid for material & in plant &
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.