Do you have any question about this error?
Message type: E = Error
Message class: HH - (Long) text for check tool 'infcfgcheck'
Message number: 064
Message text: Der spez. Pfad 'zeigt' auf dasselbe 'rawdevice' wie ein anderer Pfad
The two specified paths (relative from $INFORMIXDIR) point to the same
raw device. In this situation you can easily overwrite existing chunks
and thereby destroy the database.
Delete redundant links if they are not already being used for existing
chunks (check using 'onstat -d'). If both links are already being used
contact the Hotline to have the situation checked.
Fehlermeldungsextrakt aus SAP-System. Copyright SAP SE
HH064
- Der spez. Pfad 'zeigt' auf dasselbe 'rawdevice' wie ein anderer Pfad ?Get instant SAP help. Start your 7-day free trial now.
HH063
Der Freiplatz des spezif. Dbspace hat eine kritische Grösse erreicht
o Dbspace is called 'rootdbs' and freespace is less than 20M, but at least 10M or more o Dbspace is not called 'rootdbs': o The m...
HH062
Bitte beachten Sie, dass der Dbspace Chunks hat, die offline sind
Was verursacht dieses Problem? The specified (mirrored) dbspace has chunks which are offline.Wie behebe ich diesen Fehler? This message is only a...
HH065
Spez. Verzeichnis kann (wg. fehlender Rechte o.ä.) nicht gelesen werden
Was verursacht dieses Problem? Firstly: This message is not an error! The individual check could not execute automatically as usual. No check was m...
HH066
Bitte editieren Sie die Informix-ONCONFIG-Datei
Was verursacht dieses Problem? The ONCONFIG parameter 'PHYSFILE' is configured very low. This parameter defines the size of the physical ...