Do you have any question about this error?
Message type: E = Error
Message class: HH - (Long) text for check tool 'infcfgcheck'
Message number: 066
Message text: Bitte editieren Sie die Informix-ONCONFIG-Datei
The ONCONFIG parameter 'PHYSFILE' is configured very low.
This parameter defines the size of the physical log file in kilobytes.
If the physical log file is configured very low then there is the risk
that it could fill up in certain situations (SAP upgrade) and that the
checkpoint that results from this implicitly (due to an Informix bug)
will not be implemented (checkpoint 'hangs' in a 'critical section').
To set 'PHYSFILE' to the recommended value edit (as user 'informix')
the file '$INFORMIXDIR/etc/$ONCONFIG' or use the Informix tool
'onparams'.
CAUTION: The change will only be active after restarting the database.
Fehlermeldungsextrakt aus SAP-System. Copyright SAP SE
HH066
- Bitte editieren Sie die Informix-ONCONFIG-Datei ?Get instant SAP help. Start your 7-day free trial now.
HH065
Spez. Verzeichnis kann (wg. fehlender Rechte o.ä.) nicht gelesen werden
Was verursacht dieses Problem? Firstly: This message is not an error! The individual check could not execute automatically as usual. No check was m...
HH064
Der spez. Pfad 'zeigt' auf dasselbe 'rawdevice' wie ein anderer Pfad
Was verursacht dieses Problem? The two specified paths (relative from $INFORMIXDIR) point to the same raw device. In this situation you can easily ...
HH067
Die Anzahl der Dbspace-Chunks ist (sehr) kritisch (wg. ontape/onarchive)
Was verursacht dieses Problem? The specified dbspace consists of many chunks: Background: The Informix backup tools 'ontape' and 'on...
HH068
Bitte überprüfen Sie die 'rawdevice' Links auch manuell!
Was verursacht dieses Problem? This message is not an error! On the SINIX operating system platform, it is not possible to check whether the rawdev...
Klicken Sie auf diesen Link, um alle SAP-Meldungen durchsuchen.