How To Fix SWF_XI_ADM069 - Impossible de lancer file d'attente d'entrée pr processus &1


SWF_XI_ADM069 - Overview

  • Message type: E = Error

  • Message class: SWF_XI_ADM - XI: BPE Administration

  • Message number: 069

  • Message text: Impossible de lancer file d'attente d'entrée pr processus &1

  • Show details Hide details
  • Quelle est la cause de ce problème?

    The inbound queue &V2& for process &V1& could not be stopped.

    Réponse du système

    The starting of the Business Process Engine was canceled. This means
    that the Business Process Engine is not completely started.

    Comment corriger cette erreur?

    Check the inbound queue using qRFC administration.
    Then, try to stop the Business Process Engine completely, or restart it.

    Procédure pour les administrateurs système


    Extrait du message d'erreur du système SAP. Copyright SAP SE.