How To Fix RSQBW055 - Nom de structure append non valable -> voir texte descriptif


SAP Error Message - Details

  • Message type: E = Error

  • Message class: RSQBW -

  • Message number: 055

  • Message text: Nom de structure append non valable -> voir texte descriptif

  • Show details Hide details
  • The generation namespace is: '&V1&'
    The append name is: '&V2&'
    The total length is: '&V3&'

    Le système émet un message d'erreur et ne vous permettra pas de poursuivre cette transaction tant que l'erreur n'est pas résolue.

    <ZH>Naming:</>
    The name of an InfoSet append is formed as follows:
    without a namespace prefix
    <(><<)>TLOGO><(><<)>append name>
    ISETAPPEND0001
    with: TLOGO: ISET
    with a namespace prefix
    <(><<)>namespace prefix><(><<)>TLOGO><(><<)>append name>
    /BWTEST01/ISETTEST1
    The TLOGO name must not be changed or omitted.
    The InfoSet append name must have at least 3 characters and no more than
    10 characters. The total length is made up of the generation namespace
    of the namespace prefix and the append name.
    The namespace prefix in the append name may not be the same as a
    generation namespace. If you attempt to create /B71/ISET<(><<)>append
    name>, for example, this fails because /B71/ is the generation namespace
    for /BWTEST01/. The correct prefix would be /BWTEST01/ISET<(><<)>append
    name>.
    <ZH>Example 1 - Without a Namespace Prefix:</>
    You want to create 'ISETAPPEND0001', which is made up of:
    TLOGO object:,,,,ISET
    Append name: ,,,,APPEND0001
    The append name APPEND0001 consists of 10 characters; since the TLOGO
    name ISET is not included in the length restriction, the name is valid.
    <ZH>Example 2 - With a Namespace Prefix:</>
    You want to create '/BWTEST01/ISETTEST1', which is made up of:
    Namespace prefix:,,/BWTEST01/
    TLOGO object:,,,,ISET
    Append name: ,,,,TEST1
    The generation namespace of /BWTEST01/ is /B71/.
    The namespace /BWTEST01/ consists of 10 characters. The corresponding
    generation namespace is /B71/, which consists of 5 characters. The
    actual append name TEST1 consists of 5 characters. Since the TLOGO name
    ISET is not included in the length restriction, the name is valid.

    Extrait du message d'erreur du système SAP. Copyright SAP SE.


Smart SAP Assistant

  • Quelle est la cause et la solution de l'erreur SAP RSQBW055 - Nom de structure append non valable -> voir texte descriptif ?




    • Do you have any question about this error?


      Upgrade now to chat with this error.


Instant HelpGet instant SAP help. Start your 7-day free trial now.


Messages d'erreur SAP associés

Cliquez sur les liens ci-dessous pour voir les messages connexes suivants:

Cliquez sur ce lien pour rechercher tous les messages SAP.


Rating
ERPlingo simplifies finding the accurate answers to SAP message errors. I now use every week. A must have tool for anyone working with SAP! Highly recommended!
Rate 1
Kent Bettisworth
Executive SAP Consultant