Do you have any question about this error?
Message type: E = Error
Message class: QS - QM: Master data
Message number: 080
Message text: Les données sont prédéfinies dans la caractéristique de ctrle de base
You want to create a link to a class characteristic. To do this,
certain data has to be changed in the master inspection characteristic.
Which data must be changed depends on whether the class characteristic
is of the data type "<ZH>NUM</>" or "<ZH>CHAR</>."
If the class characteristic is of the data type "<ZH>NUM</>," the
following data is affected:
The master inspection characteristic is defined as a quantitative
characteristic. You can no longer change this setting.
For results confirmation, the "Summarized recording" indicator is set,
if the "Single value" indicator has been set in the class
characteristic.
For results confirmation, the "Single result" indicator is set, if the
"Multiple values" indicator has been set in the class characteristic.
All relevant data (for example, class width) is reset.
The "Check target value" indicator is canceled.
The tolerance key is canceled.
The "Confirm values" indicator is set and cannot be changed.
The number of digits is set to the value that is in the class
characteristic.
All limit pairs (except the specification limits) are reset.
If a unit of measurement was defined for the class characteristic, it
is copied into the master inspection characteristic and it can no
longer be changed.
If the "Required entry" indicator is set for the class characterstic,
the master inspection characteristic becomes a required characteristic;
otherwise it is an optional characteristic.
The master inspection characteristic is marked as a reference
characteristic, this means that if this characteristic is included in a
task list or material specification, it first appears as a reference.
To cancel the reference, the characteristic must be manually unlocked.
If the class characteristic is of the data type "<ZH>CHAR</>," the
following data is affected:
The master inspection characteristic is defined as a qualitative
characteristic. You cannot change this setting.
For results confirmation, the "Summarized recording" indicator is set.
You should not change this setting when the link has been created to
perform batch classification.
The "Characteristic attribute" indicator is set and cannot be changed.
The selected set from catalog type 1 contained in the class
characteristic is assigned to the master inspection characteristic. You
cannot change this selected set.
If any method-dependent selected sets from catalog type 1 are assigned
to the master inspection characteristic, they are canceled.
If the "Required entry" indicator is set for the class characterstic,
the master inspection characteristic becomes a required characteristic;
otherwise it is an optional characteristic.
The master inspection characteristic is marked as a reference
characteristic, this means that if this characteristic is included in a
task list or material specification, it first appears as a reference.
To cancel the reference, the characteristic must be manually unlocked.
Le système émet un message d'erreur et ne vous permettra pas de poursuivre cette transaction tant que l'erreur n'est pas résolue.
Ignore the warning or check the settings in the master inspection
characteristic.
Extrait du message d'erreur du système SAP. Copyright SAP SE.
QS080
- Les données sont prédéfinies dans la caractéristique de ctrle de base ?Get instant SAP help. Start your 7-day free trial now.
QS079
Le renvoi à la caractéristique de classe n'est pas repris
Quelle est la cause de ce problème? You wanted to create a master inspection characteristic using a copy model. However, the characteristic used as...
QS078
Le système poursuit le traitement de la version la plus actuelle
Quelle est la cause de ce problème? You have chosen a version from Matchcode that has an historic status. This means that there is a more up-to-dat...
QS081
Caract. de classe et caract. de ctrle de base incompatibles
Quelle est la cause de ce problème? You want to assign a class characteristic to the master inspection characteristic after the master inspection c...
QS082
Caractér.de ctrle de base comme "modèle de copie incomplet" impossible
Quelle est la cause de ce problème? You want to use a master inspection characteristic that has been changed without history as an incomplete copy ...
Cliquez sur ce lien pour rechercher tous les messages SAP.