How To Fix PYC_CONF_WB076 - La valeur sémantique &1 n'est pas valide.


SAP Error Message - Details

  • Message type: E = Error

  • Message class: PYC_CONF_WB -

  • Message number: 076

  • Message text: La valeur sémantique &1 n'est pas valide.

  • Show details Hide details
  • Quelle est la cause de ce problème?

    You see this message because this validation rule has the semantic
    category <AB>PYD_NEED</> (Needs Data) with the specified semantic value,
    but there is no validation rule that <ZH>provides </>data for it: that
    is, validation rule of semantic category <AB>PYD_CKFLTR</> (Represents a
    Check-Result-Filter Data Source Type) with the same semantic value.
    <ZH>Background</>
    One validation rule Y can use another validation rule X as filter to
    suppress the check results of Y. As a result, if an alert detected by Y
    is already raised by validation rule X, the same alert will not be shown
    by Y.
    Prior to Configuration Workbench, this is implemented in Customizing
    activity <LS>Define Check Types </>(under Customizing for <LS>Payroll ->
    Payroll International -> Payroll Control Center -> Payroll Control
    Center Configuration Simplification</>.)
    For validation rule X, which is used as filter, assign the semantic
    category <AB>PYD_CKFLTR </>and any pairing semantic value (for example,
    ABCD).
    For validation rule Y, which uses validation rule X as filter, assign
    the semantic category <AB>PYD_NEED </>and the same pairing value (ABCD
    in this case).
    RESET N1
    In Configuration Workbench, this is implemented by configuring alert
    dependencies for validation rules:
    Enable validation rule X as a filter by selecting the checkbox <LS>This
    validation rule can be used by other validation rules to suppress raised
    alerts </>on the <LS>Alert Dependencies </>tab page.
    Add validation rule X in the alert dependencies of validation rule Y on
    the <LS>Alert Dependencies </>tab page.
    With Configuration Workbench, you no longer need to enter a pairing
    value, but the validation rule ID is used automatically as the semantic
    value for <AB>PYD_CKFLTR</> if the validation rule is used as a filter.
    Solution
    The <LS>Consistency Check for Existing Objects with Configuration
    Workbench </>(<AB>PYC_SUPPORT_CWB_CONS_CHECK</>) report can update the
    configuration by removing the semantic category <AB>PYD_NEED </>and the
    semantic value from the validation rule.

    Comment corriger cette erreur?

    (Recommended) If you want the report to apply the abovementioned
    solution for you, choose <LS>Apply Solution </>in the application
    toolbar bar on the <LS>Display All Convertible Configurations </>page of
    the report.
    If you want to change the configuration by yourself, you can manually
    edit alert dependencies for relevant validation rules in Configuration
    Workbench or edit the semantic values of relevant validation rules in
    Customizing activity <LS>Define Check Types</>.

    Procédure pour les administrateurs système

    Le système émet un message d'erreur et ne vous permettra pas de poursuivre cette transaction tant que l'erreur n'est pas résolue.


    Extrait du message d'erreur du système SAP. Copyright SAP SE.


Smart SAP Assistant

  • Quelle est la cause et la solution de l'erreur SAP PYC_CONF_WB076 - La valeur sémantique &1 n'est pas valide. ?




    • Do you have any question about this error?


      Upgrade now to chat with this error.


Instant HelpGet instant SAP help. Start your 7-day free trial now.


Messages d'erreur SAP associés

Cliquez sur les liens ci-dessous pour voir les messages connexes suivants:

Cliquez sur ce lien pour rechercher tous les messages SAP.


Rating
ERPlingo's SAP support assistant is amazing. Saves me countless hours trying to solve complex SAP issues myself. It's a real game changer!
Rate 1
Thomas Michael
SAP Consultant, Author & Speaker