Do you have any question about this error?
Message type: E = Error
Message class: O3 - IS-Oil: HPM messages (goods movements, QCI, deliveries)
Message number: 232
Message text: ICQ:paramètres densité base et valeur calorifique base incohérents
You have maintained a unit of measure for the base density of a natural
gas in the conversion group that is maintained in the unit of measure
customizing table ( T006) with additional parameters ( temperature and
pressure values and units ). The base heating value that is maintained
in the conversion group is also maintained in that way. The values for
temperature and pressure have to be identical for both the base density
unit and the base heating value unit. Otherwise, the system issues this
error message and the calculation is halted, since inconsistent results
would be obtained.
Le système émet un message d'erreur et ne vous permettra pas de poursuivre cette transaction tant que l'erreur n'est pas résolue.
Change the settings in the conversion group. Enter a base density unit
and a base heating value unit that have identical parameters for
metering. Alternatively, you may remove the units of measure if no
conversion is required to the parameters attached to the units, or you
remove the flag in the conversion group that activates the additional
conversion: <DS:TRAN.O580>Change conversion group settings</>
Extrait du message d'erreur du système SAP. Copyright SAP SE.
O3232
- ICQ:paramètres densité base et valeur calorifique base incohérents ?Get instant SAP help. Start your 7-day free trial now.
O3231
QCI : Valeurs et unités de température et pression de base remplacées
Quelle est la cause de ce problème? In the conversion group, an indicator is set to activate additional conversion routines. The routines convert t...
O3230
& enreg. inactifs de val. par défaut sauveg. ; à activer avant utilisat.
Quelle est la cause de ce problème? You have maintained several default sets and saved the data. However, not all default sets have been activated ...
O3233
QCI : aucune unité avec dimension "sans unité" trouvée
Quelle est la cause de ce problème? The system tried to retrieve one unit of measure with the "dimensionless" dimension, but not one unit...
O3234
Dimension incorr. : saisissez unité qté avec dimension "sans dimension"
Message auto-explicatif Étant donné que SAP estime que ce message d'erreur spécifique est 'auto-explicatif', aucune autre information n'a été fou...
Cliquez sur ce lien pour rechercher tous les messages SAP.