Black Friday is ending this Friday! 40% off with coupon CYBER40 - Sign up here

Close

How To Fix HH081 - Editez le fichier Informix ONCONFIG


HH081 - Overview

  • Message type: E = Error

  • Message class: HH - (Long) text for check tool 'infcfgcheck'

  • Message number: 081

  • Message text: Editez le fichier Informix ONCONFIG

  • Show details Hide details
  • Quelle est la cause de ce problème?

    The ONCONFIG parameter 'OPT_GOAL' in your system is not set to the
    recommended value. This parameter influences the behavior of the cost-
    based Informix optimizer. For example, if the value is '0', the
    optimizer optimizes using FIRST_ROWS. However, this is not the correct
    standard setting. The correct setting is '-1' (or not set at all),
    which means the optimizer uses ALL_ROWS.
    'OPT_GOAL' in an SAP R/3 database must be set to the SAP recommended
    and tested value. Any other value will reduce performance considerably.

    Réponse du système

    Comment corriger cette erreur?

    To change 'OPT_GOAL', log on as user 'informix' and edit the file
    '$INFORMIXDIR/etc/$ONCONFIG'.
    CAUTION: The change is not active until the database is restarted.

    Le système émet un message d'erreur et ne vous permettra pas de poursuivre cette transaction tant que l'erreur n'est pas résolue.


    Extrait du message d'erreur du système SAP. Copyright SAP SE.


HH081 - Details








Instant HelpGet instant SAP help. Sign up for our Free Essentials Plan.


Messages d'erreur SAP associés

Cliquez sur les liens ci-dessous pour voir les messages connexes suivants:

Cliquez sur ce lien pour rechercher tous les messages SAP.


Rating
ERPlingo's SAP support assistant is amazing. Saves me countless hours trying to solve complex SAP issues myself. It's a real game changer!
Rate 1
Thomas Michael
SAP Consultant, Author & Speaker