Message text: La clé pour l'attribut EQUNR ne peut pas être transférée.
You are using a master data template in which a node of the DEVICE_INFO
category is used to create a device info record. As of Release 4.64,
the master data template category belonging to this node contains an
attribute called EQUNR. This attribute can be used to inform the
subsequent node (for example billing-related device installation) about
the newly created device info record.
However, when the master data template was executed, the system
diagnosed that EQUNR does not exist. The reason for this is that the
master data template was create while you were running a previous IS-U
release and was not changed when you upgraded to IS-U 4.64. The master
data template therefore does not recognize the new EQUNR attribute.
You can continue using the master data template. However, we recommend
that you update it. You do this as follows:
Call transaction EPRODCUST. Enter the key of the master data template
and choose the <ls>Change</> button.
Save the master data template. It now contains the new attribute.
The EQUNR attribute was introduced in Release 4.64 because this release
enables you to create several device info records for a device number
and material. If you use this functionality, ensure that you use the
equipment number for logical device installations since this number is
unique. Change your master data templates accordingly.
Le système émet un message d'erreur et ne vous permettra pas de poursuivre cette transaction tant que l'erreur n'est pas résolue.
Extrait du message d'erreur du système SAP. Copyright SAP SE.
EPROD058
- La clé pour l'attribut EQUNR ne peut pas être transférée. ?Get instant SAP help. Start your 7-day free trial now.
EPROD057
Erreur interne : aucun mode univoque existant.
Quelle est la cause de ce problème? When the master data template is executed the system has to determine a mode. This was not possible because the...
EPROD056
L'équipement &1 n'est pas une fiche info appareil appropriée.
Quelle est la cause de ce problème? The master data generator has processed a node of the DEVICE_INFO category. This node can create device info re...
EPROD059
La fiche info appareil équipement &1 existait déjà.
Quelle est la cause de ce problème? You have executed a master data template that has a node of the DEVICE_ INFO category for creating device info ...
EPROD060
Incohérence lors détermination de l'environnement de données.
Quelle est la cause de ce problème? The environment determination functions of the master data generator identified an inconsistency in the data en...
Cliquez sur ce lien pour rechercher tous les messages SAP.