Do you have any question about this error?
Message type: E = Error
Message class: EL - IS-U meter reading data processing
Message number: 206
Message text: Appar. & cdrn &2 date &3 : l'index ne peut pas être déterminé automat.
This is caused by one of the following:
The register has no rate category
Therefore no rate and no weighting key could be determined for the
extrapolation.
The register has no rate type
Therefore no rate and no weighting key could be determined for the
extrapolation.
There are insufficient meter reading results for the device for the
extrapolation to be representative.
In this case, the system required a period consumption. However no
period consumption was entered when the device was installed.
Extrapolation is terminated
If the register does not have a rate category or an installation
structure enter them in the contract or in the installation structure
to which the register belongs.
If there are insufficient meter reading results for extrapolation to be
representative, create a <DS:TRAN.EL56>period consumption</> for the
appropriate register.
Extrait du message d'erreur du système SAP. Copyright SAP SE.
EL206
- Appar. & cdrn &2 date &3 : l'index ne peut pas être déterminé automat. ?Get instant SAP help. Start your 7-day free trial now.
EL205
Saisie impossible pour contrat &1 ; voir &2 (&3)
Message auto-explicatif Étant donné que SAP estime que ce message d'erreur spécifique est 'auto-explicatif', aucune autre information n'a été fou...
EL204
App. &1 cdrn &2 date rel. : date relevé antérieure à pose de l'appareil.
Message auto-explicatif Étant donné que SAP estime que ce message d'erreur spécifique est 'auto-explicatif', aucune autre information n'a été fou...
EL207
Il est impossible d'annuler le motif de relevé & entré.
Quelle est la cause de ce problème? You cannot use the function for reversing meter reading orders to delete meter reading results with this meter ...
EL208
La clé de période &1 est introuvable dans le module fonction &2.
Quelle est la cause de ce problème? It is possible that no period key was entered for a PROFEST value in the installation structure in which the co...