Do you have any question about this error?
Message type: E = Error
Message class: CNV_IUUC_TCR_MAIN - transactional consistent replication main package
Message number: 008
Message text: Impossible de créer table de protocole &1 pour table cluster &2 (RC &3)
This message uses return codes that help to identify the issue that
occurred in the source system when creating the logging table. The
following return codes are possible:
110: A logging table with the same name already exists and it has a
different structure.
12X: It was not possible to create the cluster definition in the source
(function module DD_SQLT_PUT).
13X: It was not possible to update the technical settings for the
logging table (function module DD_TABT_PUT).
140: It was not possible to create the needed TADIR entry in the source
(function module TR_TADIR_INTERFACE).
150: It was not possible to set storage parameters.
16X: It was not possible to activate the table in the source.
Le système émet un message d'erreur et ne vous permettra pas de poursuivre cette transaction tant que l'erreur n'est pas résolue.
For return code 110, check the source system for the already existing
logging table. If the table exists, it was most likely created with
different settings. You need to verify whether the table in the source
is correct. If not, you can try to delete the table in the source and
start the creation process for the logging table again in the central
system. It is also possible that an inconsistency in the central system
exists where the wrong logging table name is associated with the table
and the table in the source is used for another application table. In
this case check the values in tables IUUC_TABLES, IUUC_TCR_TABLES2 and
IUUC_TCR_CLUS_ID for the respective tables and IDs.
For all other return codes, there is either a general issue in the
source system, or the logging table needs to be checked by an expert
(specifically how the logging table was created). Consult your SAP
contact in the project team.
Extrait du message d'erreur du système SAP. Copyright SAP SE.
CNV_IUUC_TCR_MAIN008
- Impossible de créer table de protocole &1 pour table cluster &2 (RC &3) ?Get instant SAP help. Start your 7-day free trial now.
CNV_IUUC_TCR_MAIN007
Aucun nouveau numéro disponible dans l'objet de tranche de numéros &1
Quelle est la cause de ce problème? In order to generate the name for a logging table, the system needs to retrieve a new number from the number ra...
CNV_IUUC_TCR_MAIN006
Impossible d'initialiser l'objet de tranche de numéros &1
Quelle est la cause de ce problème? In order to generate the name for a logging table, the system needs to initialize the number range object. The ...
CNV_IUUC_TCR_MAIN009
Impossible de créer table d'alias &1 pour table &2 du cluster &3 (RC &4)
Quelle est la cause de ce problème? In order to read data from the logging table for a cluster table, a so called alias table is needed. It represe...
CNV_IUUC_TCR_MAIN010
Aucune table logique trouvée pour table cluster &1 dans le système source
Quelle est la cause de ce problème? The table was classified to be a cluster table in the central system. However when checking the source system, ...
Cliquez sur ce lien pour rechercher tous les messages SAP.