Do you have any question about this error?
Message type: E = Error
Message class: RSM1 - Messages for AWB, Scheduler and Monitor (new)
Message number: 608
Message text: Borrar inicializaciones tiene repercusiones en objetos DataStore
You want to delete executed initializations, registered in the delta
administration, from the delta administration.
If you delete initializations from the delta administration, only the
delta administration in BW and in the source system is reset. You can
then only request deltas again when you have reinitialized this
DataSource/source system combination.
Warning
When you delete the initialization from the delta administration, no
data is deleted from the system.
Important Note on DataStore Objects
If the delta process of your DataSource stipulates serialization, you
can no longer post this init request or any subsequently requested delta
requests to the DataStore objects that were filled previously, after you
have deleted the initialization and reinitialized. This is because old
inits and deltas still exist.
The DataStore object recognizes that new inits and deltas have been
created that are not yet posted in the DataStore object and requires
them to be updated. Otherwise the selections of the new inits overlap
with the selections of the old inits that are still in the DataStore
object, so that they cannot be posted.
The system does not activate the newly-loaded inits or deltas in the
DataStore object if the delta process of the DataSource stipulates
serialization.
After deleting the init administration, also delete the data that was
loaded with this init and the deltas that followed into the DataSource
objects from these DataSource objects, if the delta process of the
DataSource stipulates serialization.
Otherwise new inits or deltas cannot be activated in this DataStore
object.
(This is not checked when the inits or deltas are loaded to the
activation queue, but when they are activated).
El sistema emite un mensaje de error y no le permitirá continuar con esta transacción hasta que se resuelva el error.
Extracto de mensaje de error del sistema SAP. Copyright SAP SE.
RSM1608
- Borrar inicializaciones tiene repercusiones en objetos DataStore ?Get instant SAP help. Start your 7-day free trial now.
RSM1607
Para campo sel.& no se permiten selecciones con SIGN = &; OPTION &
Mensaje autoexplicativo Dado que SAP cree que este mensaje de error específico 'se explica por sí mismo', no se ha proporcionado más información. ...
RSM1606
Conversión hexadecimal->carácter da errores internos: Cancelación
Mensaje autoexplicativo Dado que SAP cree que este mensaje de error específico 'se explica por sí mismo', no se ha proporcionado más información. ...
RSM1609
Simulación init y solicitud early delta juntas no tienen sentido
Mensaje autoexplicativo Dado que SAP cree que este mensaje de error específico 'se explica por sí mismo', no se ha proporcionado más información. ...
RSM1610
Asignación de FD &1 de SF &2 modificada de IF &3 a IF &4 -> Txt.expl.
¿Qué causa este problema? Mapping of DataSource &V1& from source system &V2& has changed. Before, the DataSource was assigned to In...
Haga clic en este enlace para buscar todos los mensajes de SAP.