Message type: E = Error
Message class: QE - RM-QSS Fehlertexte zur Ergebniserfassung
Message number: 717
Message text: No fue posible determinar los límites del gráfico ctrl. p. huella &1
The control limits for track &V1& on the control chart cannot be
calculated with the existing data.
The function was not carried out.
The procedure depends on the type of track and the type of inspection
characteristic. The following options are available:
In the case of an average value track, the standard deviations of the
samples are required to calculate the limits.
In the case of <ZH>summarized recording</>, you can enter these in the
single screen for the characteristic.
In the case of <ZH>classified recording</> or <ZH>recording of
individual values</>, the standard deviation is only determined
automatically during the valuation. In order to initiate the
calculation before the valuation is performed, call the function for
recording the statistical moments.
In the case of an average value track for an acceptance chart, if the
dispersion is large or the tolerance range is small, then the value
for the upper control limit can sometimes be less than that of the
lower control limit.
If this happens, then you should repeat the calculation at a later
date,when the dispersion has decreased.
Individual algorithms can often require a certain minimum number of
inspection results before a calculation is possible.
The exact requirements depend on the procedure stored for the track in
the Customizing application.
Extracto de mensaje de error del sistema SAP. Copyright SAP SE.
QE717
- No fue posible determinar los límites del gráfico ctrl. p. huella &1 ?Get instant SAP help. Start your 7-day free trial now.
QE716
Huella &1 del gráfico de control no contiene datos
¿Qué causa este problema? The track &V1& <ZH> &V2& </> of the control chart called does not contain any data.Respuesta ...
QE715
Criterio SPC y característica no combinable
¿Qué causa este problema? The desired SPC criterion is not compatible with the inspection characteristic. An SPC criterion can only be assigned if ...
QE718
Se anula indicador característica SPC
¿Qué causa este problema? You have used a master inspection characteristic in which the <ZH>SPC inspection</> indicator is set to defin...
QE719
La función no está soportada
¿Qué causa este problema? The function that you selected is not supported in this control chart track. You can, for example, display the process ca...